Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ART GALVANIZING WORKS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ART GALVANIZING WORKS, INC. in 3935 VALLEY ROAD, CLEVELAND, OH 44109 (NAICS 332312). OSHA activity number 342411667.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ART Galvanizing Works, INC. for free Get an email when a new federal OSHA severe-injury report for ART Galvanizing Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3935 VALLEY ROAD
City
CLEVELAND
State
OH
ZIP
44109
Mailing
3935 VALLEY ROAD, CLEVELAND, OH 44109
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
30
Ownership type
Private (A)

2 citations on file for this inspection.

1910.252 A03 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1910.252(a)(3)(i): Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present:    On or about 6/6/2017, the employer failed to ensure that the barrels were cleaned prior to cutting them with a torch.
Recent events (2)
  • · I (S) $8873
  • · Z (S) $8873

1910.252 A03 II

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2017
Penalty
Initial $8,873 · Current $0 Reduced
29 CFR 1910.252(a)(3)(ii): All hollow spaces, cavities, or containers were not vented to permit the escape of air or gases before preheating, cutting, or welding was performed:    On or about June 6th, 2017, the employer failed to ensure that the 55 gallon drums were adequately vented prior to cutting them with a torch.
Recent events (2)
  • · I (S) $0
  • · Z (S) $8873

View ART Galvanizing Works, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342411667.