RIDGECREST, CA ·
OSHA Inspection: NAVAL FACILITIES ENGINEERING COMMAND - CHINA LAKE FIRE SUPPRESSION SHOP
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of NAVAL FACILITIES ENGINEERING COMMAND - CHINA LAKE FIRE SUPPRESSION SHOP in BUILDING 01483, RIDGECREST, CA 93555 (NAICS 928110). OSHA activity number 342415551.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- BUILDING 01483
- City
- RIDGECREST
- State
- CA
- ZIP
- 93555
- Mailing
- 429 EAST BOWEN AVENUE STOP 4007, RIDGECREST, CA 93555
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 8
- Ownership type
- Federal government (D)
Citations
2 citations on file for this inspection.
1910.253 B04 III
- Issued
- Dec 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: Employees working near the front entrance of the building were exposed to fire and explosion hazards in that an oxygen cylinder was stored next to an acetylene cylinder and less than five feet from a propane cylinder.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 F06 II
- Issued
- Dec 5, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical Employees working in the fire suppression shop were exposed to fire and explosion hazards in that a compressed gas cylinder, likely containing propane, was not labeled to indicate the contents of the container.
Recent events (2)
- · I (O) $0
- · Z (S) $0
More inspections at Naval Facilities Engineering Command - China Lake Fire Suppression Shop
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342415551.