OSHA Inspection: AUTOMOTIVE SUPER SPORTS INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AUTOMOTIVE SUPER SPORTS INC. in 3001 NE 21ST WAY, GAINESVILLE, FL 32609 (NAICS 811121). OSHA activity number 342415874.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Automotive Super Sports INC. for free Get an email when a new federal OSHA severe-injury report for Automotive Super Sports INC. is published. One employer, no account, unsubscribe in one click.
Site address
3001 NE 21ST WAY
City
GAINESVILLE
State
FL
ZIP
32609
Mailing
3001 NE 21ST WAY, GAINESVILLE, FL 32609
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
20
Ownership type
Private (A)

4 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 5 1 instance 8 exposed
Issued
Oct 5, 2017
Abate by
Oct 18, 2017
Penalty
Initial $2,897 · Current $1,738 Reduced

Hazardous substances 00402037

29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  a. On or about June 29, 2017, storage and tool cleaning area behind the spray mixing shop, the employer failed to ensure that the "Paint Thinner" dispensing and waste solvent drum were grounded to prevent the accumulation of static electricity, which could be an ignition source to "Paint Thinner" and other flammable vapors.
Recent events (2)
  • · I (S) $1738.2
  • · Z (S) $2897

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Oct 5, 2017
Abate by
Nov 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   a) On or about June 19, 2017, paint area, employees were required to wear a tight-fit half face respirator while spray-painting automobile parts and the employer failed to establish and implement a written respiratory protection program.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.242 B

Other-than-serious 1 instance 8 exposed
Issued
Oct 5, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a. On or about June 29, 2017, automotive body shop, the employer failed to ensure that the employees using compress-air for the cleaning of auto parts, used nozzles  where the pressure was reduced from approximately 100 psi to less than 30 psi or that the nozzles were equipped with a safety tip, to protect employees from possible injury to the eyes or embolism.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 20 exposed
Issued
Oct 5, 2017
Abate by
Nov 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) On or about June 19, 2017, the employer failed to develop and implement a written Hazard Communication Program for the protection of the employees, that use hazardous chemicals, including but not limited to AXALTA's "Epoxy Primer", "Chroma-Premier System" and "Nason Aerosol".
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342415874.