Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: SUNBRIDGE CARE & REHAB FOR DECATUR

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUNBRIDGE CARE & REHAB FOR DECATUR in 1350 14TH AVENUE SE, DECATUR, AL 35601 (NAICS 623110). OSHA activity number 342416112.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunbridge Care & Rehab for Decatur for free Get an email when a new federal OSHA severe-injury report for Sunbridge Care & Rehab for Decatur is published. One employer, no account, unsubscribe in one click.
Site address
1350 14TH AVENUE SE
City
DECATUR
State
AL
ZIP
35601
Mailing
1350 14TH AVENUE SE, DECATUR, AL 35601
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
50
Ownership type
Private (A)

2 citations on file for this inspection.

1910.151 C

Other-than-serious 1 instance 4 exposed
Issued
Aug 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) On or about June 21, 2017 - East Hall, the eyewash station was not suitable in that a controlled flow of flushing liquid was not provided to ensure that velocity did not cause injury to the employee and the installed control valve did not ensure tepid temperature was delivered.
Recent events (1)
  • · Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 2 exposed
Issued
Aug 29, 2017
Abate by
Oct 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  (a) On or about June 21, 2017 - Laundry Room, working spaces behind the washer and dryers to the electrical disconnects were less than 36 inches.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342416112.