Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAY DENTAL LAB INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BAY DENTAL LAB INC in 8814 ROCKY CREEK DR, TAMPA, FL 33615 (NAICS 339116). OSHA activity number 342417193.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BAY Dental LAB INC — free Get an email when a new federal OSHA severe-injury report for BAY Dental LAB INC is published. One employer, no account, unsubscribe in one click.
Establishment
BAY DENTAL LAB INC
Site address
8814 ROCKY CREEK DR
City
TAMPA
State
FL
ZIP
33615
Mailing
8814 ROCKY CREEK DR, TAMPA, FL 33615
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339116
Employees
7
Ownership type
A

3 citations on file for this inspection.

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) In the Model Room, as observed on or about 06/21/2017, employees used voluntarily a 3M N95 (Model 8511) respirator for particulates.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Dec 20, 2017
Abate by
Feb 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a)   At the Model Room, as observed on or about 06/21/2017 and 12/08/17, for employees handling irritant dust from model stones and plasters.
Recent events (1)
  • — Z (O) $0

1910.1200 H03 IV

Other-than-serious 1 instance 1 exposed
Issued
Dec 20, 2017
Abate by
Feb 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:  a) At the Model Room, as observed on or about 06/21/2017 and 12/08/17, for employees handling irritant dust from model stones and plasters who were not trained on the new labeling system and pictograms.
Recent events (1)
  • — Z (O) $0