Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DALLAS MFG (GTS, MTA)

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DALLAS MFG (GTS, MTA) in 12827 AND 12828 VALLEY BRANCH LANE, DALLAS, TX 75234 (NAICS 332216). OSHA activity number 342417847.

Watch Dallas MFG (GTS, MTA) — free Get an email when a new federal OSHA severe-injury report for Dallas MFG (GTS, MTA) is published. One employer, no account, unsubscribe in one click.
Site address
12827 AND 12828 VALLEY BRANCH LANE
City
DALLAS
State
TX
ZIP
75234
Mailing
12827 VALLEY BRANCH LANE, DALLAS, TX 75234
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332216
Employees
308
Ownership type
A

3 citations on file for this inspection.

1910.147 C05 II D

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $7243.00 · Current $3622.00 Reduced
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):     a)  The employer did not ensure lockout devices indicate the identity of the employee applying the devices. On or about June 20, 2017, employee applied locks to the spin welder S2089, model YL45B, and to the main circuit breaker without indicating the identity of the employee applying the devices.
Recent events (3)
  • — F (O) $3621.5
  • — C (S) $7243
  • — Z (S) $7243

1910.147 C06 I

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $4527.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about June 20, 2017, and at times prior thereto, the employer did not conduct a periodic inspection of the energy control procedure at least annually.
Recent events (3)
  • — F (O) $4527
  • — C (S) $9054
  • — Z (S) $9054

1910.305 B01 II

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $4527.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) The employer did not close unused openings on electrical equipment.  This violation was observed on or about June 20, 2017, and July 13, 2017, at building 27, near to the break room, where electrical panel was missing circuit breakers.
Recent events (3)
  • — F (O) $4527
  • — C (S) $9054
  • — Z (S) $9054

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342417847.