Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: RB CUSTOM WELDING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RB CUSTOM WELDING LLC in 5210 E 10TH AVE, TAMPA, FL 33619 (NAICS 332710). OSHA activity number 342419306.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RB Custom Welding LLC for free Get an email when a new federal OSHA severe-injury report for RB Custom Welding LLC is published. One employer, no account, unsubscribe in one click.
Site address
5210 E 10TH AVE
City
TAMPA
State
FL
ZIP
33619
Mailing
5210 E 10TH AVE, TAMPA, FL 33619
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
7
Ownership type
Private (A)

4 citations on file for this inspection.

1910.243 C01 II A

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 30, 2017
Abate by
Dec 12, 2017
Penalty
Initial $1,630 · Current $815 Reduced
29 CFR 1910.243(c)(1)(ii)(a): Safety guard(s) on portable abrasive wheel(s) were not mounted so as to maintain proper alignment with the wheel:  a) In fabrication, an employee was using a Porter-Cable PC750AG 4.5 inch Small Angle Grinder, serial number 2016 52-JL without a guard while cutting aluminum, on or about June 23, 2017.
Recent events (2)
  • · I (S) $815
  • · Z (S) $1630

1910.134 K06

Other-than-serious 1 instance 1 exposed
Issued
Nov 30, 2017
Abate by
Dec 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a) In the production area, fabricating employees were provided disposable two strap N95 respirators for voluntary use when welding on aluminum, on or about June 23, 2017.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.334 A02 I

Other-than-serious 3 instances 2 exposed
Issued
Nov 30, 2017
Abate by
Dec 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) In fabrication, an employee was using an extension cord with a damaged outer jacket covered by black electrical tape to supply power to a Porter-Cable PC750AG 4.5 inch Small Angle Grinder, on or about June 23, 2017.  b) In fabrication, an employee was using an extension cord with a missing ground pin to supply power to a Porter-Cable PC750AG 4.5 inch Small Angle Grinder, on or about June 23, 2017.  c) In fabrication, an employee was using a portable fan with a missing ground pin, on or about June 23, 2017.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.334 A03 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 30, 2017
Abate by
Dec 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles:  (a) In fabrication, an employee was using an extension cord with a missing ground pin to supply power to a Porter-Cable PC750AG 4.5 inch Small Angle Grinder, on or about June 23, 2017.  (b) In fabrication, an employee was using a portable fan with a missing ground pin on the plug of the power cord, on or about June 23, 2017.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342419306.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.