EL PASO, TX —
OSHA Inspection: SJ CONCRETE PUMPING SERVICES,LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SJ CONCRETE PUMPING SERVICES,LLC in 9985 ROSA M. RICHARDSON, EL PASO, TX 79927 (NAICS 238110). OSHA activity number 342421146.
Where did this inspection happen?
- Establishment
- SJ CONCRETE PUMPING SERVICES,LLC
- Site address
- 9985 ROSA M. RICHARDSON
- City
- EL PASO
- State
- TX
- ZIP
- 79927
- Mailing
- 11985 PELLICANO DR., STE G, BOX 315, EL PASO, TX 79936
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: Construction Site: On or about June 22, 2017, the employer did not ensure that employee retained the requisite understanding or skill on the operation of the pump truck mounted boom controls. This condition exposed employee to electrical shock hazards.
Recent events (2)
- — I (O) $2500
- — Z (S) $3803
1926.600 A06 II
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.600(a)(6)(ii): For lines rated over 50 kV, a minimum of 10 feet plus 0.4 inch for each 1 kV over 50 kV, or twice the length of the line insulator was not maintained between the energized line and any part of the equipment or load: Construction Site: On or about June 22, 2017, the employee was operating the pump truck mounted boom controls without having a view of boom tip. The Supervisor (spotter) allowed the boom tip to get within 10 feet of the energized electrical line. This condition exposed employee to electrical shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $3803
More inspections in this industry (NAICS 238110)
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
NAMPA, ID—2026-07-15
ICON BUILDING SOLUTIONS LLC
DULUTH, MN—2026-07-14
111602 - JMF CONSTRUCTION INC
REDDING, CA—2026-07-14
EMERGENT CONSTRUCTION, INC.
CLEVELAND, OH—2026-07-14
MIENCORP MASONRY
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342421146.