Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FELCO INDUSTRIES, LLC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FELCO INDUSTRIES, LLC. in 3660 GRANT CREEK RD., MISSOULA, MT 59801 (NAICS 811310). OSHA activity number 342422763.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Felco Industries, LLC. for free Get an email when a new federal OSHA severe-injury report for Felco Industries, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3660 GRANT CREEK RD.
City
MISSOULA
State
MT
ZIP
59801
Mailing
3660 GRANT CREEK RD., MISSOULA, MT 59801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
48
Ownership type
Private (A)

9 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $5,387 · Current $3,232 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   a. Spray Area: On or about June 20, 2017, and at times prior, employees were exposed to respiratory hazards associated with working with Ecologic Rustex Direct to Metal Primer 70323 while wearing a 3M half mask elastomeric respirator with NIOSH 6001 cartridges without having had an annual fit test.   b. Spray Area: On or about June 20, 2017, and at times prior, employees were exposed to respiratory hazards associated with working with Ecologic Rustex Direct to Metal Primer 70323 while wearing a 3M half mask elastomeric respirator with NIOSH 6001 cartridges without having procedures for regularly evaluating the effectiveness of the program.
Recent events (2)
  • · I (S) $3232.2
  • · Z (S) $5387

1910.242 B

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $3,231 · Current $1,939 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a. Machine Shop: On or about June 20, 2017, and at times prior, employees were exposed to air embolisms and/or struck by hazards while using compressed air to clean off workstations with a compressor tip set at >100 p.s.i.
Recent events (2)
  • · I (S) $1938.6
  • · Z (S) $3231

1910.304 F01 VIII

Serious Gravity 5 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $6,464 · Current $3,878 Reduced
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD."  a. Spray Area: On or about June 20, 2017, and at times prior, employees were using a circuit breaker in place of a switch to operate the fluorescent lighting in the Spray Area.
Recent events (2)
  • · I (S) $3878.4
  • · Z (S) $6464

1910.1200 F06 II

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $3,232 · Current $1,939 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  a. Iron Worker Area: On or about June 20, 2017, and at times prior, employees were exposed to unknown chemical hazards while working with Long Life 20/20 Plus Cutting Fluid in a spray bottle without proper GHS demarcation.
Recent events (2)
  • · I (S) $1939.2
  • · Z (S) $3232

1910.134 C02 I

Other-than-serious 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a. Main Shop: On or about June 20, 2017, and at times prior, employees were exposed to hazards associated with not understanding the proper care and maintenance of wearing N-95 dust masks during clean up operations.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 F02

Other-than-serious 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a. Spray Area: On or about June 20, 2017, and at times prior, the employees were using a panel board to energize and de-energize equipment throughout the day without clear demarcation on what the machines or devices the individual circuit breakers control.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01

Other-than-serious 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a. Plasma Cutter and Saw Area: On or about June 20, 2017, and at times prior, employees were exposed to hazards associated with not being able to access the electrical control panel and shut down equipment in the event of an emergency.  b. Welding Area Near Back Wall: On or about June 20, 2017, and at times prior, employees were exposed to hazards associated with not being able to access the electrical control panel and shut down equipment in the event of an emergency.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a. Welder Station: On or about June 20, 2017, and at times prior, employees were using handheld angle grinders connected to a flexible extension cord with exposed wiring near the joint.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 13 exposed
Issued
Aug 23, 2017
Abate by
Sep 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a. Felco Industrial: On or about June 20, 2017, and at times prior, employees were exposed to chemical hazards while performing welding operations, working with Long Life 20/20 Plus, and performing Spray finishing operations without having been adequately trained on the hazards associated with working with these chemicals.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342422763.