Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BUGAJ CONSTRUCTION COMPANY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUGAJ CONSTRUCTION COMPANY LLC in 284 LALLEY BOULEVARD, FAIRFIELD, CT 06824 (NAICS 238170). OSHA activity number 342423779.

Watch Bugaj Construction Company LLC — free Get an email when a new federal OSHA severe-injury report for Bugaj Construction Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
284 LALLEY BOULEVARD
City
FAIRFIELD
State
CT
ZIP
06824
Mailing
478 HOLLYDALE ROAD, FAIRFIELD, CT 06824
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

8 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2173.00 · Current $2173.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  Location:  284 Lalley Boulevard, Fairfield, CT 06824    The poles of a pump jack scaffold were set up on grass and were not set on a firm foundation such as but not limited base plates.
Recent events (1)
  • — Z (S) $2173

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2173.00 · Current $2173.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  Location: 284 Lalley Boulevard, Fairfield, CT 06824    A feasible means of access (portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist) to the scaffold platform on the aluminum pump jack scaffold was not provided.
Recent events (1)
  • — Z (S) $2173

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  Location:  Jobsite, 284 Lalley Boulevard, Fairfield, CT 06824  Each employee working on an aluminum pump jack scaffold installing wood siding was within 3 feet of an energized power line.
Recent events (1)
  • — Z (S) $2716

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  Location:  284 Lalley Boulevard, Fairfield, CT 06824    The aluminum pump jack scaffold was not erected under the supervision and direction of a competent person qualified in scaffold erection.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  Location: 284 Lalley Boulevard, Fairfield, CT 06824    The scaffold platform on the aluminum pump jack scaffold 15 feet above the ground was not equipped with a fall protection systems and/or devices.
Recent events (1)
  • — Z (S) $2716

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2173.00 · Current $2173.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  Location:  284 Lalley Boulevard, Fairfield, CT 06824    The poles of the aluminum pump jack scaffold were not secured at the bottom and were susceptible to being displaced.
Recent events (1)
  • — Z (S) $2173

1926.454 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  Location:  284 Lalley Boulevard, Fairfield, CT 06824    Each employee performing work on an aluminum pump jack scaffold was not trained by a qualified person in the appropriate subject matter to be able to recognized hazards and know what procedures to use to control or minimize those hazards.
Recent events (1)
  • — Z (S) $1630

1926.454 B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.  Location:  284 Lalley Boulevard, Fairfield, CT 06824    Each employee involved in erecting, disassembling, moving, moving, maintaining or inspecting aluminum pump jack scaffolds were not trained by a competent person to recognize scaffolding, fall, and other hazards associated with scaffolds.
Recent events (1)
  • — Z (S) $0