Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SK JR PROPERTIES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SK JR PROPERTIES INC. in 6 VICTORY FALLS ROAD, COVENTRY, RI 02816 (NAICS 238110). OSHA activity number 342424579.

Watch SK JR Properties INC. — free Get an email when a new federal OSHA severe-injury report for SK JR Properties INC. is published. One employer, no account, unsubscribe in one click.
Site address
6 VICTORY FALLS ROAD
City
COVENTRY
State
RI
ZIP
02816
Mailing
875 DIVISION ROAD, EAST GREENWICH, RI 02818
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
2
Ownership type
A

1 citation on file for this inspection.

1926.701 A

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3803.00 · Current $2660.00 Reduced
29 CFR 1926.701(a): Construction loads were placed on a concrete structure or portion of a concrete structure without the employer having determined, based on information received from a person who was qualified in structural design, that the structure or portion of the structure was capable of supporting the loads:    (a) Jobsite: The employer operating the CAT 316E excavator in close proximity to the foundation wall of the residential foundation under construction did not determine, based on information received from a person who was qualified in structural design, that the structure or portion of the structure was capable of supporting the load on or about 7/26/17, and resulting in the collapse of a portion of the foundation wall.
Recent events (2)
  • — I (S) $2660
  • — Z (S) $3803