DOTHAN, AL —
OSHA Inspection: CUMMINGS RESOURCES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CUMMINGS RESOURCES, LLC in 4255 NAPIER FIELD ROAD, DOTHAN, AL 36301 (NAICS 339950). OSHA activity number 342435484.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUMMINGS RESOURCES, LLC
- Site address
- 4255 NAPIER FIELD ROAD
- City
- DOTHAN
- State
- AL
- ZIP
- 36301
- Mailing
- 4255 NAPIER FIELD ROAD, DOTHAN, AL 36301
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 180
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 15, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $9,778 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) Plant Floor/Shuman Former Machine (Former #3 & #4): On or about June 28, 2017 and at times prior, the employer exposed employees to amputation hazards, in that employees were allowed perform set-up operations on, but not limited to, the Shuman Former Machine (Former #3 & #4) without developing, documenting or utilizing lockout/tagout energy control procedures to prevent accidental startup of the machine.
Recent events (2)
- — I (S) $5000
- — Z (S) $9778
1910.147 C07 I A
- Issued
- Aug 15, 2017
- Abate by
- Sep 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) Plant Floor/Shuman Former Machine (Former #3 & #4): On or about June 28, 2017 and at times prior, the employer exposed employees to amputation hazards, in that employees were allowed perform set-up operations on, but not limited to, the Shuman Former Machine (Former #3 & #4) without first being trained to ensure those employees had the knowledge and skills to identify hazardous energy sources, and to safely apply, use, and remove energy controls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 A04
- Issued
- Aug 15, 2017
- Abate by
- Aug 25, 2017
- Penalty
- Initial $6,519 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Automation Dept/Yard: On or about June 28, 2017 and at times prior, the employer exposed employees to struck-by and crushed-by hazards, in that employees were allowed to operate the C-150 Daewoo forklift that had an attachment of unknown manufacturer. The attachment was not certified by the forklift manufacturer and did not have updated instruction plates, tags, or decals.
Recent events (2)
- — I (S) $5000
- — Z (S) $6519
1904.39 A02
- Issued
- Aug 15, 2017
- Abate by
- Aug 25, 2017
- Penalty
- Initial $8,149 · Current $5,000 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. a) Mold Shop: On or about June 28, 2017 and at times prior, the employer had an employee amputate his left index finger midway between the fingertip and the nail bed. The employer failed to report the work-related hospitalization to OSHA within twenty-four (24) hours.
Recent events (2)
- — I (O) $5000
- — Z (O) $8149
1910.147 C05 II
- Issued
- Aug 15, 2017
- Abate by
- Aug 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout/Tagout devices shall be the only devices used for controlling energy, shall not be used for other purposes and meet the requirements of 1910.147(c)(5)(ii) [A] thru 1910.147(c)(5)(ii)[D] a) Plant Floor/Former Machine (Former #1 Forming Oven): On or about June 28, 2017 and at times prior, the employer exposed employees to amputation and other hazards, in that the locks applied to the breaker panel of Former Machine #1 did not identify the employee who applied the lock.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cummings Resources, LLC
View Cummings Resources, LLC's full OSHA safety record →
More inspections in this industry (NAICS 339950)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342435484.