Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PERFORMANCE PALLET CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PERFORMANCE PALLET CORP. in 112 N MAINLINE DRIVE, SEYMOUR, WI 54165 (NAICS 321920). OSHA activity number 342437886.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Performance Pallet Corp. — free Get an email when a new federal OSHA severe-injury report for Performance Pallet Corp. is published. One employer, no account, unsubscribe in one click.
Site address
112 N MAINLINE DRIVE
City
SEYMOUR
State
WI
ZIP
54165
Mailing
112 N MAINLINE DR, SEYMOUR, WI 54165
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
168
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 17, 2017
Penalty
Initial $8,149 · Current $4,075 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    On or about June 19, 2017, employees working on the B&B Manufacturing Wood PAKer machine located in the loading dock were exposed to pinch points created between the moving firewood basket bar and fixed support bar.
Recent events (2)
  • — I (S) $4074.5
  • — Z (S) $8149

1910.305 G01 IV D

Deleted Other-than-serious 1 instance 10 exposed
Issued
Jul 17, 2017
Abate by
Aug 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where attached to building surfaces;  On or about June 26, 2017, a flexible cord used to power the B&B Manufacturing Wood PAKer machine was attached to the ceiling trusses with zip ties.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Performance Pallet Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342437886.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.