Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIRGAS USA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AIRGAS USA, LLC in 1100 EMMETT STREET, AUGUSTA, GA 30904 (NAICS 325120). OSHA activity number 342439221.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Airgas USA, LLC — free Get an email when a new federal OSHA severe-injury report for Airgas USA, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AIRGAS USA, LLC
Site address
1100 EMMETT STREET
City
AUGUSTA
State
GA
ZIP
30904
Mailing
5311 77 CENTER DRIVE, CHARLOTTE, NC 28217
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325120
Employees
35
Ownership type
A

2 citations on file for this inspection.

1910.138 A

Other-than-serious 1 instance 1 exposed
Issued
Jul 20, 2017
Abate by
Aug 22, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.138(a): The employer did not assure that its employee was using appropriate hand protection when the employee's hands were exposed to a frostbite hazard.    (a) New Cryogenic freezer room  on or about January 23, 2017, an employee was exposed to a   frostbite hazard while shutting off a valve, without using  protective gloves, during the charging of a cryogenic freezer.
Recent events (3)
  • — F (O) $12675
  • — C (S) $12675
  • — Z (S) $12675

5(a)(1)

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jul 20, 2017
Abate by
Aug 22, 2017
Penalty
Initial $12,675 · Current $0 Reduced

Hazardous substances 1900

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to an employee in that the employee was exposed to asphyxia and hypothermia hazards created by a liquid nitrogen cryogenic system in which the outdoor bulk nitrogen tank was not labeled to correctly indicate the bulk tank internal pressure and house line pressure required for safe operation.                                                                                                                                                      a) New cryogenic freezer room - On or about January 23, 2017 an employee installing/testing cryogenic freezers was exposed to asphyxia and hypothermia hazards when the outdoor bulk nitrogen tank was over-pressured due to a mislabeling of the tank internal pressure and house line pressure, causing the bulk tank contents to vent inside the new room.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records
Recent events (3)
  • — F (S) $0
  • — C (S) $12675
  • — Z (S) $12675

View Airgas USA, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342439221.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.