HARRISONVILLE, MO ·
OSHA Inspection: BELA FLOR NURSERIES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BELA FLOR NURSERIES in 28615 SE OUTER RD, HARRISONVILLE, MO 64701 (NAICS 424930). OSHA activity number 342445996.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELA FLOR NURSERIES
- Site address
- 28615 SE OUTER RD
- City
- HARRISONVILLE
- State
- MO
- ZIP
- 64701
- Mailing
- 28615 SE OUTER RD, HARRISONVILLE, MO 64701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424930
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.28 B01 I
- Issued
- Oct 16, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $6,338 · Current $1,585 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): (1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: guardrail systems, safety net systems, or personal fall protection systems: Employees are exposed to fall hazards. Employees were exposed to falls of 11 feet when working from the green house guttering system. Employees were not protected by use of guardrail systems, safety net systems, or personal fall arrest systems.
Recent events (3)
- · F (S) $1584.5
- · C (S) $6338
- · Z (S) $6338
1910.134 E01
- Issued
- Oct 16, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $5,070 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Employees were exposed to respiratory hazards. Employees were required to wear a full faced respirator when spraying pesticides. There was no medical evaluation provided for employees prior to mandatory use of the Moldex full faced respirator.
Recent events (3)
- · F (S) $1267.5
- · C (S) $5070
- · Z (S) $5070
1910.134 F02
- Issued
- Oct 16, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: Employees were exposed to respiratory hazards. Employees were required to wear a full faced respirator when spraying pesticides. Employees were not fit tested prior to mandatory use of the Moldex full faced respirator.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.147 C04 II B
- Issued
- Oct 16, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $6,338 · Current $1,585 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Employees were exposed to electrical hazards. There were no machine specific written procedures for the Transplanting Lines. The Transplanting lines include conveyors, and a hopper for dirt.
Recent events (3)
- · F (S) $1584.5
- · C (S) $6338
- · Z (S) $6338
1910.151 C
- Issued
- Oct 16, 2017
- Penalty
- Initial $5,070 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Employees were exposed to eye injuries from corrosive materials. Employees were exposed to Corrosive Liquid containing Sulfuric Acid, and Ammonium Bifluoride in the Green Tank/Mixing Area. Employees are exposed to corrosive liquids and there was no eye wash and shower station available to provide a 15 minute flush.
Recent events (3)
- · F (S) $1267.5
- · C (S) $5070
- · Z (S) $5070
1910.178 Q05
- Issued
- Oct 16, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $5,070 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.178(q)(5): Parts of powered industrial trucks requiring replacement were not replaced with parts equivalent in safety with those used in the original design. Employees were exposed to struck by hazards as the TCM propane forklift had pedals that did not have a nonskid surface. The TCM propane forklift also had a rear backup light that was not working. The TCM forklift had not been taken out of service until it was in safe operating condition.
Recent events (3)
- · F (S) $1267.5
- · C (S) $5070
- · Z (S) $5070
More inspections in this industry (NAICS 424930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342445996.