Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SCOTLAND HARDWOODS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCOTLAND HARDWOODS, LLC in 117 ZIEGLER ROAD, SCOTLAND, CT 06264 (NAICS 321113). OSHA activity number 342446937.

Watch Scotland Hardwoods, LLC — free Get an email when a new federal OSHA severe-injury report for Scotland Hardwoods, LLC is published. One employer, no account, unsubscribe in one click.
Site address
117 ZIEGLER ROAD
City
SCOTLAND
State
CT
ZIP
06264
Mailing
P.O. BOX 328, SCOTLAND, CT 06264
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.265 C05 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4310.00 · Current $2000.00 Reduced
29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side:    Maintenance Room:  A ten-step 41 1/2" wide stairway leading to the storage mezzanine was not provided with a standard handrail on the open side.  Employees were exposed to 8-foot falls to the ground below.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4310

1910.303 B07 III

Serious Gravity 5 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $4310.00 · Current $2000.00 Reduced
29 CFR 1910.303(b)(7)(iii):  Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, may not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues:      A.  On or about July 6, 2017, Trim Saw Area:  A junction box at the side of the Irvington Trim Saw was missing a cover, which allowed the accumulation of sawdust in the box near capped energized wires.    B.  On or about July 6, 2017, Debarking Area:  The cover of a 2-receptacle 110V outlet box was displaced, and could allow sawdust to accumulate near the energized wires.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4310

1910.304 G06 VI C 8

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $2747.00 · Current $2000.00 Reduced
29 CFR 1910.304(g)(6)(vi)(C)(8): Exposed noncurrent-carrying metal parts of portable hand lamp that may become energized was not grounded:    A.  On or about July 6, 2017, Debarking Area:  An ungrounded 2-wire metal-encased clip-on work light was energized and available for use.  When turning on the lamp, employees could contact the ungrounded metal parts when activating the toggle switch, exposing them to electric shock hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2747

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342446937.