Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PYRAMID CONTRACTORS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PYRAMID CONTRACTORS, INC in 17104 PIERCE ST, OMAHA, NE 68130 (NAICS 236115). OSHA activity number 342447091.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pyramid Contractors, INC — free Get an email when a new federal OSHA severe-injury report for Pyramid Contractors, INC is published. One employer, no account, unsubscribe in one click.
Site address
17104 PIERCE ST
City
OMAHA
State
NE
ZIP
68130
Mailing
5532 CENTER ST, OMAHA, NE 68106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
50
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2017
Abate by
Aug 25, 2017
Penalty
Initial $6,338 · Current $6,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    The employer is failing to ensure that employees exposed to fall hazards while working on a residential roof are utilizing fall protection.  This most recently occurred on June 27, 2017 on the jobsite located at 17104 Pierce St, Omaha, NE 68130.  An employee was observed on the roof of a 2-story residence performing an inspection while re-roofing work was going on.  1926.500(a)(1) states that this standard applies because construction work was in progress.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $6338

1926.501 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2017
Abate by
Aug 25, 2017
Penalty
Initial $5,070 · Current $0 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    The employer is failing to ensure that employees exposed to fall hazards while working on a residential roof are utilizing fall protection.  This most recently occurred on June 27, 2017 on the jobsite located at 17104 Pierce St, Omaha, NE 68130.  An employee was observed performing an inspection on the roof of a 2-story residence.  The roof has 2 skylights and re-roofing work was in progress.  1926.500(a)(1) states that this standard applies because construction work was in progress.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5070

1926.1053 B06

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2017
Abate by
Aug 25, 2017
Penalty
Initial $6,338 · Current $5,000 Reduced
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement:    The employer is failing to ensure that all employees are protected from fall hazards when using a ladder to transition from the garage roof to the roof of the residence.  This most recently occurred on June 27, 2017 on the jobsite located at 17104 Pierce St, Omaha, NE 68130.  An employee is using an aluminum folding ladder to gain access from the garage roof to the upper level of a 2-story residence.  The ladder is placed on an uneven surface and not secured to prevent accidental displacement.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $6338

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2017
Abate by
Aug 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder:    The employer is failing to ensure that all employees are protected from fall hazards when entering and exiting the landing surface of a residential roof.  This most recently occurred on June 27, 2017 on the jobsite located at 17104 Pierce St, Omaha, NE 68130.  An employee is using an aluminum folding ladder to enter and exit the 2nd story roof where the side rails were not extended to at least 3 feet above the landing surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Pyramid Contractors, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342447091.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.