Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAVECO ENERGY SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAVECO ENERGY SYSTEMS, INC. in PARK AVENUE, CRESSKILL, NJ 07626 (NAICS 238160). OSHA activity number 342453859.

Watch Daveco Energy Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Daveco Energy Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
PARK AVENUE
City
CRESSKILL
State
NJ
ZIP
07626
Mailing
313 TENTH STREET, CARLSTADT, NJ 07072
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3259.00 · Current $1304.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:                                                                                                             A) Exterior, On roof: An employee was exposed to eye/face injuries while using an electric saw and was not protected with any type of eye/face protection, on or about May 3rd, 2017.
Recent events (2)
  • — I (S) $1303.6
  • — Z (S) $3259

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3803.00 · Current $1521.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     A) Roof: An employee was exposed to fall hazards of approximately 32 feet while conducting roofing work on the roof of a structure without a means of fall protection in place, on or about May 3rd, 2017.
Recent events (2)
  • — I (S) $1521.2
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $1521.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    A) Exterior, Roof Level: Employees were exposed to fall hazards of approximately 25 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about May 3rd, 2017.
Recent events (2)
  • — I (S) $1521.2
  • — Z (S) $3803

1926.1053 B04

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3803.00 · Current $1521.00 Reduced
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:   A) Exterior, Roof: An employee was exposed to fall/ladder collapse hazards as the folding step ladder being used was not opened and locked into place, on or about May 7th, 2016.
Recent events (2)
  • — I (S) $1521.2
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342453859.