Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIKO

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MIKO in 7010 LOW BID LANE, SAN ANTONIO, TX 78250 (NAICS 237210). OSHA activity number 342454493.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miko — free Get an email when a new federal OSHA severe-injury report for Miko is published. One employer, no account, unsubscribe in one click.
Establishment
MIKO
Site address
7010 LOW BID LANE
City
SAN ANTONIO
State
TX
ZIP
78250
Mailing
5315 VERBENA, SAN ANTONIO, TX 78240
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237210
Employees
8
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 8 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $2,217 · Current $2,217
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by flying projectiles:      Maintenance Yard:  On or about July 21, 2017, employees were exposed to the hazard of being stuck by flying projectiles, while operating compressed air equipment.  The compressed air used by the equipment was transported above grade via 3/4" PVC Pipe at an operating pressure of approximately 130 psi.
Recent events (1)
  • — Z (S) $2217

1910.134 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  Maintenance Yard: On or about July 21, 2017, employees were exposed to health hazards when the employer did not establish a written respiratory protection program or implement provisions of the program such as, but not limited to, medical evaluations or fit tests, for employees who were required to wear MSA Comfo Classic respirators with P-100/Multi gas cartridges.
Recent events (1)
  • — Z (S) $2217

1910.146 C04

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  Navistar International Transportation Corp Water Truck:  On or about July 21, 2017, an employee was exposed to confined space hazards such as oxygen deficiency and IDLH, while entering a water truck reservoir to apply SEAL-GAP sealant without the employer developing and implementing a written permit space entry program.
Recent events (1)
  • — Z (S) $3880

1910.146 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:  Navistar International Transportation Corp Water Truck:  On or about July 21, 2017, an employee was exposed to confined space hazards such as oxygen deficiency and IDLH atmospheres, while entering a water truck reservoir to apply SEAL-GAP sealant without being trained to perform functions under permit required confined spaces.
Recent events (1)
  • — Z (S) $0

1910.146 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1910.146(k)(1): An employer who designates rescue and emergency services, pursuant to paragraph (d)(9)of this section did not evaluate the prospective rescuer's ability by the criteria set in this section, (k)(1)(i) - (k)(1)(v):  Navistar International Transportation Corp Water Truck:  On or about July 21, 2017, an employee was exposed to confined space hazards such as oxygen deficiency and IDLH atmospheres, while entering a water truck reservoir to apply SEAL-GAP Sealant without having a coworker available to call for emergency rescue services.
Recent events (1)
  • — Z (S) $3880

1910.253 B04 III

Serious Gravity 5 1 instance 8 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  Maintenance storage connex: On or about July 21, 2017, employees were exposed to a fire hazard due to an oxygen compressed gas cylinders, stored next to acetylene compressed gas cylinder and Ful-Fil 421-08 Acrylic Primer-Surfacer.
Recent events (1)
  • — Z (S) $2217

1910.305 B01 I

Serious Gravity 5 2 instances 8 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:    Connex:  On or about July 21, 2017, and at times prior thereto, employees were exposed to electrical hazards, while using an air compressor that did not have strain relief to protect conductors from abrasion.
Recent events (1)
  • — Z (S) $2772

1910.305 B02 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jan 17, 2018
Abate by
Feb 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose.  In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy:    Connex: On or about July 21, 2017, employees were exposed to electrical hazards while using an air compressor that had electrical conductors running through a junction box that had a missing cover plate.
Recent events (1)
  • — Z (S) $0

View Miko's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342454493.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.