JEFFERSONVILLE, OH ·
OSHA Inspection: HAMBURG FIREWORKS DISPLAY INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HAMBURG FIREWORKS DISPLAY INC in 2375 ST. RT. 734, JEFFERSONVILLE, OH 43128 (NAICS 713990). OSHA activity number 342454782.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAMBURG FIREWORKS DISPLAY INC
- Site address
- 2375 ST. RT. 734
- City
- JEFFERSONVILLE
- State
- OH
- ZIP
- 43128
- Mailing
- 2240 HORNS MILL ROAD, LANCASTER, OH 43130
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713990
- Employees
- 200
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 7, 2017
- Abate by
- Jun 11, 2019
- Penalty
- Initial $11,408 · Current $7,204 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to a blast and fragmentation hazard during an outdoors fireworks display. On July 4, 2017 at an outdoor field in Jeffersonville, crew members were exposed to a blast and fragmentation hazard while lighting fuses on mortar shells in racks and not moving away from the mortar shell when the fuse was lit. Feasible abatement: National Fire Protection Association (NFPA) 1123-2006 Code for Fireworks Display paragraph 8.2.6.2. stated that once a fuse is lit, the shooter shall vacate the mortar area.
Recent events (3)
- · F (S) $7204
- · C (S) $11408
- · Z (S) $11408
1910.132 A
- Issued
- Sep 7, 2017
- Abate by
- Jun 11, 2019
- Penalty
- Initial $11,408 · Current $7,204 Reduced
General-duty citation text
29 CFR 1910.132(a): Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. The employer had not provided and ensured the use of flame-resistant clothing to employees exposed to a burn hazard while working in the outdoors fireworks display area.
Recent events (3)
- · F (O) $7204
- · C (S) $11408
- · Z (S) $11408
More inspections in this industry (NAICS 713990)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342454782.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.