Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAMES A. HALEY VETERANS' HOSPITAL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAMES A. HALEY VETERANS' HOSPITAL in 13000 BRUCE B DOWNS BLVD,, TAMPA, FL 33612 (NAICS 622110). OSHA activity number 342457298.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch James a. Haley Veterans' Hospital — free Get an email when a new federal OSHA severe-injury report for James a. Haley Veterans' Hospital is published. One employer, no account, unsubscribe in one click.
Site address
13000 BRUCE B DOWNS BLVD,
City
TAMPA
State
FL
ZIP
33612
Mailing
13000 BRUCE B DOWNS BLVD,, TAMPA, FL 33612
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
5000
Ownership type
D

4 citations on file for this inspection.

1910.213 A09

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(a)(9): Belts, pulleys, gears, shafts,and moving parts were not guarded in accordance with the specific requirements of 1910.219.  (a)  At the site- in the mechanic shop the Kalamazoo Bandsaw #ee58716 was not guarded exposing the employees to an amputation hazard, on or about 7/12/2017.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   (a)  At the site - in the workshop the metal electrical box was not mounted as required by the manufacturer, on or about 07/12/2017.
Recent events (1)
  • — Z (O) $0

1910.303 G01

Other-than-serious 3 instances 2 exposed
Issued
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  At the site- in the kitchen the electrical panel box was blocked, on or about 7/12/2017.  (b)  At the site - in the bed shop the electrical panel box was blocked, on or about 07/12/2017.  (c)  At the site - in the plumbing shop the electrical panel box was blocked, on or about 07/12/2017.
Recent events (1)
  • — Z (O) $0

1910.334 A03 I

Other-than-serious 3 instances 2 exposed
Issued
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor:  (a)  At the site - the Dayton 18" band saw was missing the ground pin, on or about 07/12/2017.
Recent events (1)
  • — Z (O) $0

View James a. Haley Veterans' Hospital's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342457298.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.