Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OSHKOSH DOOR COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OSHKOSH DOOR COMPANY in 2501 UNIVERSAL STREET, OSHKOSH, WI 54904 (NAICS 321911). OSHA activity number 342459815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oshkosh Door Company — free Get an email when a new federal OSHA severe-injury report for Oshkosh Door Company is published. One employer, no account, unsubscribe in one click.
Site address
2501 UNIVERSAL STREET
City
OSHKOSH
State
WI
ZIP
54904
Mailing
2501 UNIVERSAL STREET, OSHKOSH, WI 54904
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
128
Ownership type
A

17 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 14, 2017
Abate by
Dec 20, 2017
Penalty
Initial $5,542 · Current $3,879 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a)    On or about 7/12/2017, Employees were doing foil replacement on #9 Glue line while standing on loading basket with a potential fall height of 4' to 8' approximately once per month.
Recent events (2)
  • — I (S) $3879.4
  • — Z (S) $5542

1910.134 C

Serious Gravity 5 2 instances 3 exposed
Issued
Nov 14, 2017
Abate by
Dec 20, 2017
Penalty
Initial $6,926 · Current $4,848 Reduced
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  a)    On or about 7/12/2017, Employer had not developed and implemented a written respiratory program for protection of employees using respirators in the painting and sanding operations.
Recent events (2)
  • — I (S) $4848.2
  • — Z (S) $6926

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $6,926 · Current $4,848 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a)    On or about 7/12/2017, employer was adding 447-LM chemical to its water treatment system and did not have emergency eye wash facilities in close proximity to the chemical mixing operation.
Recent events (2)
  • — I (S) $4848.2
  • — Z (S) $6926

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 14, 2017
Abate by
Dec 20, 2017
Penalty
Initial $6,926 · Current $4,848 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)    On or about 7/12/2017, The KVAL machines had pinch points that were created by the movement of the routers.  b)    On or about 7/12/2017, On the east side of the Hot Press there was a guard door missing leaving approximately a 36" wide x 5' high fence area not guarded.
Recent events (2)
  • — I (S) $4848.2
  • — Z (S) $6926

1910.213 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:  a)    On or about 7/12/2017. The radial arm saw in the core guard area was not equipped with a device to fully enclose the blade and adjust to the material being cut.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a)    On or about 7/12/2017, The company had a Dayton 10" Bench Grinder in the maintenance shop with approximately 3/4" between the tongue guard and the abrasive wheel periphery.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 1 instance 12 exposed
Issued
Nov 14, 2017
Penalty
Initial $5,542 · Current $3,879 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  a)    On or about 7/12/2017, There was a cover missing from the NS bus duct above the return finishing return line.
Recent events (2)
  • — I (S) $3879.4
  • — Z (S) $5542

1910.303 B07 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): Electric equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  a)    On or about 7/12/2017, there was an electrical box cover and wiring pulled loose from the junction box above the glue spreader.  b)    On or about 7/12/2017, the electrical cabinet in the diked area by glue spreader had rusted out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a)    On or about 7/12/2017, The lathe in the maintenance shop was being fed power from an unlabeled disconnect at the ceiling above the milling machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a)    On or about 7/12/2017, The lathe in the maintenance shop was being fed power from a temporary electrical cable at the ceiling above the milling machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed:   a)    On or about 7/12/2017, The receptacle cover was broken off and/or missing for two electrical boxes on the west exterior of the building exposing live contacts to the elements.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested as required by 1910.137.   a)    On or about 7/12/2017, The gloves for live electrical work had not been tested since August 2014 and were available for use in the maintenance shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B04

Other-than-serious 8 instances 85 exposed
Issued
Nov 14, 2017
Abate by
Dec 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  a)    On or about 7/12/2017 Emergency exit signs were not readily available to direct employees to the nearest exit from the core line and other finishing areas of the plant.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.107 B06

Other-than-serious 1 instance 2 exposed
Issued
Nov 14, 2017
Abate by
Dec 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(6): Spray booth(s) having a frontal area larger than 9 square feet did not have metal deflectors or curtains not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening:  a)    On or about 7/12/2017,The paint booth in the finishing area was not equipped with a metal deflector or curtain installed at the upper outer edge over the booth opening.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.107 C07

Other-than-serious 1 instance 2 exposed
Issued
Nov 14, 2017
Abate by
Dec 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area, and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles:  a)    On or about 7/12/2017,The paint booth in the finishing area was not separated by 20 feet or a partition from the ceiling lighting which was not designed for spray booth exposure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.159 C02

Other-than-serious 2 instances 12 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.159(c)(2): The employer did not properly maintain the installed automatic sprinkler system:  a)    On or about 7/12/2017, Sprinkler heads in the maintenance and receiving restrooms were partially blocked with foam insulation which would have affected the spray pattern for the sprinklers if they were set off by a fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 3 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.  a)    On or about 7/12/2017, The milling machine in the maintenance shop was not secured to the floor to keep it from moving during operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Oshkosh Door Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342459815.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.