OSHA Inspection: WOLFE PAC PELLETS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WOLFE PAC PELLETS, LLC in 1288 NW SAWMILL ROAD, MOUNTAIN HOME, ID 83647 (NAICS 311119). OSHA activity number 342463262.

Watch Wolfe PAC Pellets, LLC — free Get an email when a new federal OSHA severe-injury report for Wolfe PAC Pellets, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1288 NW SAWMILL ROAD
City
MOUNTAIN HOME
State
ID
ZIP
83647
Mailing
1288 NW SAWMILL ROAD, MOUNTAIN HOME, ID 83647
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311119
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1358.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i).  a) On or about July 10, 2017 or prior thereto: Wolfe Pac Pellets, LLC in Mountain Home, ID did not ensure that live parts of a 480V circuit breaker panel were guarded against accidental contact, exposing employees to electrical hazards. The dead front to the Shaker Waste Auger had been removed as well as restart buttons on doors of other panels.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1358
  • — Z (S) $2716

1910.305 D02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.  (a) On or about July 10, 2017 or prior thereto: Wolfe Pac Pellets, LLC in Mountain Home, ID exposed an employee to electrical hazards when a dead front was removed from a panelboard of a 480V circuit breaker panel to access the Shaker Waste Auger.     NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about July 10, 2017 or prior thereto: Wolfe Pac Pellets, LLC in Mountain Home, ID did not ensure that periodic inspection of the energy control procedures were conducted at least annually.   NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View WOLFE PAC PELLETS, LLC's full OSHA safety record →