Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: FAB WELD STEEL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FAB WELD STEEL, INC. in 3491 COUNTY ROAD 73, RANDOLPH, AL 36792 (NAICS 332312). OSHA activity number 342463882.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FAB Weld Steel, INC. — free Get an email when a new federal OSHA severe-injury report for FAB Weld Steel, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3491 COUNTY ROAD 73
City
RANDOLPH
State
AL
ZIP
36792
Mailing
P.O. BOX 158, RANDOLPH, AL 36792
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
34
Ownership type
A

4 citations on file for this inspection.

1910.179 G01 V

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2017
Abate by
Sep 7, 2017
Penalty
Initial $4,310 · Current $2,371 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:    (a) On or about 07/12/2017 - Production area, the pendant control box for the 5-Ton, DESHAZO overhead crane was not clearly marked.
Recent events (2)
  • — I (S) $2370.5
  • — Z (S) $4310

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2017
Penalty
Initial $4,310 · Current $2,371 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a) On or about 07/12/2017 - Fabrication area, the 480-volt circuit breaker panel did not have a protective cover installed to prevent contact with energized conductors.
Recent events (2)
  • — I (S) $2370.5
  • — Z (S) $4310

1910.28 B11 II

Other-than-serious 1 instance 1 exposed
Issued
Aug 25, 2017
Abate by
Sep 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(11)(ii): (ii) Each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows:   (a) On or about 07/12/2017 - Maintenance shop, the stairs leading to the miscellaneous job area were missing a mid-rail on one side and top rail and mid-rail on the other side.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.179 J03

Other-than-serious 1 instance 2 exposed
Issued
Aug 25, 2017
Abate by
Sep 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:  (a) On or about 07/12/2017 - Production area, the 5-Ton DESHAZO overhead crane had not been inspected in approximately 2 years.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View FAB Weld Steel, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342463882.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.