Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AE KIDOS AIR CONDITIONING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AE KIDOS AIR CONDITIONING in 3261 JOE BATTLE, EL PASO, TX 79938 (NAICS 238220). OSHA activity number 342468493.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AE Kidos AIR Conditioning for free Get an email when a new federal OSHA severe-injury report for AE Kidos AIR Conditioning is published. One employer, no account, unsubscribe in one click.
Site address
3261 JOE BATTLE
City
EL PASO
State
TX
ZIP
79938
Mailing
2925 WYOMING AVE, EL PASO, TX 79903
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
9
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 29, 2017
Abate by
Sep 29, 2017
Penalty
Initial $3,803 · Current $2,600 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels by personal fall arrest systems, covers, or guardrail systems erected around such holes:      On or about July 12, 2017, an employee working around an unprotected roof opening of approximate 34 by 40 inch that was 6 feet or more above the ground was not protected from falling.  This condition exposed employee to a fall hazards.
Recent events (2)
  • · I (S) $2600
  • · Z (S) $3803

1926.503 C03

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 29, 2017
Abate by
Sep 29, 2017
Penalty
Initial $1,630 · Current $0 Reduced
29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill:    On or about July 12, 2017, the employer did not ensure that employees retained the knowledge on use of fall protection systems or equipment. This condition exposed employees to fall hazards greater than 6 feet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1630

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342468493.