OSHA Inspection: WINPAK FILMS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WINPAK FILMS INC. in 100 WIHURI PKWY, SENOIA, GA 30276 (NAICS 326111). OSHA activity number 342470218.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Winpak Films INC. for free Get an email when a new federal OSHA severe-injury report for Winpak Films INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WINPAK FILMS INC.
Site address
100 WIHURI PKWY
City
SENOIA
State
GA
ZIP
30276
Mailing
100 WIHURI PKWY, SENOIA, GA 30276
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
320
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 11, 2017
Penalty
Initial $6,157 · Current $3,694 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  a) Extrusion Area: On or about July 13, 2017, and at times prior, the employer exposed employees to struck-by, caught-in, and electrical shock hazards, in that no specific procedures to control hazardous electrical energy were developed for the extrusion machine station serial number BSF07.
Recent events (2)
  • · I (S) $3694.2
  • · Z (S) $6157

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Aug 11, 2017
Abate by
Sep 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  a) Extrusion Station BSF07, South stairs: On or about July 13, 2017, and at times prior, the employer exposed employees to fire hazards in that a fire extinguisher (Badger 5 Pound Model B5V Serial Number 91009745) was not properly mounted.  b) Extrusion Station BSF01, Access Gate:  On or about July 13, 2017, and at times prior, the employer exposed employees to fire hazards in that a fire extinguisher (Badger 5 Pound Model B5V Serial Number 91009760) was not properly identified.