FRIDAY HARBOR, WA ·
OSHA Inspection: NATIONAL PARK SERVICE, SAN JUAN ISLAND NATIONAL HISTORIC PARK, MAINTENANCE FACILITY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, SAN JUAN ISLAND NATIONAL HISTORIC PARK, MAINTENANCE FACILITY in 4585 WEST VALLEY ROAD, FRIDAY HARBOR, WA 98250 (NAICS 712190). OSHA activity number 342478948.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 4585 WEST VALLEY ROAD
- City
- FRIDAY HARBOR
- State
- WA
- ZIP
- 98250
- Mailing
- P.O. BOX 429, FRIDAY HARBOR, WA 98250
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 4
- Ownership type
- Federal government (D)
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 24, 2017
- Abate by
- Sep 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) The Alamo tractor mounted mower was taken apart occasionally to sharpen the blades in the carpentry shop and there was not a written lockout tagout procedure for this operation.
Recent events (1)
- · Z (S) $0
1910.176 B
- Issued
- Aug 24, 2017
- Abate by
- Sep 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: a) Equipment Shed; A ladder jack, insulation, and handicap parking stencils were stored on the building rafters and the rafters were not load rated to ensure they did not collapse under a weighted load. b) Equipment Shed Covered Garage; Extra large heavy duty cardboard boxes were stored on the building rafters and the rafters were not load rated to ensure they did not collapse under a weighted load.
Recent events (1)
- · Z (S) $0
1910.213 S06
- Issued
- Aug 24, 2017
- Abate by
- Sep 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards: a) Carpenter Shop; Sawdust had accumulated underneath the Delta Rockwell 10 inch Unisaw table saw enclosure and on the floor.
Recent events (1)
- · Z (S) $0
1910.215 A04
- Issued
- Aug 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Carpenter Shop; The Wissota Grinders (no. N568) right tool rest measured ¼ inch from the grinding wheel.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Aug 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Carpenter Shop; The Wissota Grinders (no. N568) left tongue guard measured ½ an inch from the grinding wheel.
Recent events (1)
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Aug 24, 2017
- Abate by
- Sep 28, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Carpenter Shop; The Milwaukee 12 inch Sliding Compound Miter saw (serial no. B26-A910020092) was plugged into an orange extension cord.
Recent events (1)
- · Z (S) $0
1910.157 E02
- Issued
- Aug 24, 2017
- Abate by
- Sep 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) Carpenter Shop; The Pemall fire extinguisher was not visually inspected monthly. b) Storage Area; The Pemall fire extinguisher was not visually inspected monthly. c) Equipment Room; The Amerex fire extinguisher was not visually inspected monthly.
Recent events (1)
- · Z (O) $0
1910.157 E03
- Issued
- Aug 24, 2017
- Abate by
- Sep 28, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Carpenter Shop; The Pemall fire extinguishers last annual maintenance check was December 2010. b) Storage Area; The Pemall fire extinguishers last annual maintenance check was December 2010. c) Equipment Room; The Amerex fire extinguisher did not have a tag and the date of the last annual maintenance check was unknown.
Recent events (1)
- · Z (O) $0
More inspections at National Park Service, SAN Juan Island National Historic Park, Maintenance Facility
More inspections in this industry (NAICS 712190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342478948.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.