Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANCHOR CONSTRUCTION CORPORATION

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ANCHOR CONSTRUCTION CORPORATION in 100 Q ST., SW, WASHINGTON, DC 20003 (NAICS 237110). OSHA activity number 342479235.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anchor Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Anchor Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
100 Q ST., SW
City
WASHINGTON
State
DC
ZIP
20003
Mailing
2259 25TH PLACE, NE, WASHINGTON, DC 20018
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
10
Ownership type
A

1 citation on file for this inspection.

1926.651 B03

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 29, 2017
Abate by
Oct 10, 2017
Penalty
Initial $9,761 · Current $9,761
29 CFR 1926.651(b)(3): When excavation operations approached the estimated location of underground installations, the exact location of the installations was not determined by safe and acceptable means:   a) West Side of Building - On or about June 5, 2017, workers did not use safe and acceptable means to determine the exact location of an existing underground installation, in that, a backhoe and employees using conventional hand tools were the only means employed to determine the exact location of a n existing duct bank during a repair operation.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $9761
  • — C (S) $9761
  • — Z (S) $9761

View Anchor Construction Corporation's full OSHA safety record →