OSHA Inspection: NATIONAL PARK SERVICE, SAN JUAN ISLAND NATIONAL HISTORIC PARK, ENGLISH CAMP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, SAN JUAN ISLAND NATIONAL HISTORIC PARK, ENGLISH CAMP in 3905 WEST VALLEY ROAD, FRIDAY HARBOR, WA 98250 (NAICS 712190). OSHA activity number 342479821.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service, SAN Juan Island National Historic Park, English Camp for free Get an email when a new federal OSHA severe-injury report for National Park Service, SAN Juan Island National Historic Park, English Camp is published. One employer, no account, unsubscribe in one click.
Site address
3905 WEST VALLEY ROAD
City
FRIDAY HARBOR
State
WA
ZIP
98250
Mailing
P.O. BOX 429, FRIDAY HARBOR, WA 98250
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
4
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.176 B

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 24, 2017
Abate by
Sep 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Storage of material created a hazard:  a)  Storehouse;  A green canoe was stored up in the building rafters and the rafters were not load rated to ensure they didnt collapse under a weighted load.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2017
Abate by
Sep 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)  English Barracks; An orange extension cord was powering a reloctable power tap (surge protector) (which was powering a cash register and credit card machine) and another orange extension cord was plugged into the relocatable power tap (surge protector) which powered a second relocatable power tap (surge protector) (which was used to power bookcase lights). The UL listing states that relocatable power taps are designed to be plugged into an outlet, and not daisy chained and plugged into other relocatable power taps or extension cords.  This exposes employees to possible electrical fire hazards.
Recent events (1)
  • · Z (S) $0

1910.157 E02

Other-than-serious 1 instance 3 exposed
Issued
Aug 24, 2017
Abate by
Sep 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a)  Storehouse;  An Amerex fire extinguisher had not been inspected monthly.    This exposes employees to potential smoke inhalation hazards and other fire related hazards.
Recent events (1)
  • · Z (O) $0

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Aug 24, 2017
Abate by
Sep 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a)  Storehouse;  An Amerex fire extinguishers last annual inspection was December 2010.    This exposes employees to potential smoke inhalation hazards and other fire related hazards.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342479821.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.