THROOP, PA —
OSHA Inspection: SCRANTON CRAFTSMEN, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SCRANTON CRAFTSMEN, INC. in 930 DUNMORE STREET, THROOP, PA 18512 (NAICS 332323). OSHA activity number 342481496.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCRANTON CRAFTSMEN, INC.
- Site address
- 930 DUNMORE STREET
- City
- THROOP
- State
- PA
- ZIP
- 18512
- Mailing
- 930 DUNMORE STREET, THROOP, PA 18512
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 61
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 C05
- Issued
- Sep 14, 2017
- Abate by
- Dec 31, 2017
- Penalty
- Initial $3,879 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.107(c)(5): Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s): a) Spray Area: An employee sprayed flammable primer onto railings and non-approved electrical installations (standard electrical outlet, LED lights, and hoist motor) were located adjacent to the spray area, in a Class I Division 2 area, and subject to overspray accumulation, as discovered on or about 08/25/2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2250
- — Z (S) $3879
1910.132 D01
- Issued
- Sep 14, 2017
- Abate by
- Oct 19, 2017
- Penalty
- Initial $3,879 · Current $0 Reduced
1377
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) Spray Area: An employee sprayed an isocyanate based catalyst that necessitated the use of personal protective equipment and the employer did not perform a hazard assessment for this job, as discovered on or about 07/19/2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3879
1910.133 A01
- Issued
- Sep 14, 2017
- Abate by
- Oct 19, 2017
- Penalty
- Initial $0 · Current $2,250
1377
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Spray Area: An employee mixed and sprayed hazardous chemicals and did not wear eye protection, as discovered on or about 07/19/2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2250
- — Z (S) $0
1910.138 A
- Issued
- Sep 14, 2017
- Penalty
- Initial $0 · Current $0
1377
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous condition(s): a) Spray Area: An employee wore porous cotton gloves while mixing and spraying an isocyanate based catalyst that necessitated the use of chemical resistant gloves, as discovered on or about 07/19/2017. ABATEMENT DURING INSPECTION NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Sep 14, 2017
- Penalty
- Initial $0 · Current $0
1377
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a) Spray Area: An employee was required to wear a tight-fitting elastomeric respirator during spraying operations and was not provided with an annual fit test, as discovered on or about 07/19/2017. CORRECTED DURING INSPECTION NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Sep 14, 2017
- Abate by
- Oct 19, 2017
- Penalty
- Initial $0 · Current $0
1377
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Spray Area: An employee worked with the isocyanate containing chemical, Sherwin Williams Polane Catalyst, and was not provided with hazard communication training specific to isocyanate exposure, as discovered on or about 07/19/2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Scranton Craftsmen, INC.
View Scranton Craftsmen, INC.'s full OSHA safety record →