Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STIPP CONSTRUCTION GROUP LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STIPP CONSTRUCTION GROUP LLC in 4901 INDIAN LANE NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 342483310.

Watch Stipp Construction Group LLC — free Get an email when a new federal OSHA severe-injury report for Stipp Construction Group LLC is published. One employer, no account, unsubscribe in one click.
Site address
4901 INDIAN LANE NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
14504 CARONA DRIVE, SILVER SPRING, MD 20905
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $0.00 Reduced
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.      a) On or about June 28, 2017; second floor area of new residential construction; employee was not wearing eye protection exposing him to a potential eye injury while operating a pneumatic nail gun to secure the rafters.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.501 B13

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about June 28, 2017; Second floor area of new residential construction; employees were not wearing fall protection exposing them to a 27- 30 foot fall to ground level while working off the top-plate to install the rafters on the residential home.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.1052 C01 II

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $0.00 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge  a) On or about June 28, 2017; Second floor area of new residential construction; employees were usingan unprotected stairway, exposing the employees to a 10-foot  fall to the lower wooden deck while accessing the third floor.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.1053 B01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface, the ladder's lside rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about June 28, 2017; Second floor area of new residential construction; employees were using a step ladder to access the work area, which was an estimated 5 feet too short, exposing them to an estimated 25-30 foot fall to ground level or 10 foot fall to the deck area.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.1053 B13

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a) On or about June 28, 2017; Second floor area of new residential construction; employees were using the top step of a 5-foot step ladder to access the work area exposing them to a 10 foot fall to the wooden floor area or an estimated 25-30 feet to ground level.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0