WASHINGTON, DC ·
OSHA Inspection: STIPP CONSTRUCTION GROUP LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STIPP CONSTRUCTION GROUP LLC in 4901 INDIAN LANE NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 342483310.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STIPP CONSTRUCTION GROUP LLC
- Site address
- 4901 INDIAN LANE NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 14504 CARONA DRIVE, SILVER SPRING, MD 20905
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Sep 8, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $3,803 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about June 28, 2017; second floor area of new residential construction; employee was not wearing eye protection exposing him to a potential eye injury while operating a pneumatic nail gun to secure the rafters. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $3803
1926.501 B13
- Issued
- Sep 8, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $3,803 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about June 28, 2017; Second floor area of new residential construction; employees were not wearing fall protection exposing them to a 27- 30 foot fall to ground level while working off the top-plate to install the rafters on the residential home. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $3803
1926.1052 C01 II
- Issued
- Sep 8, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $3,803 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge a) On or about June 28, 2017; Second floor area of new residential construction; employees were usingan unprotected stairway, exposing the employees to a 10-foot fall to the lower wooden deck while accessing the third floor. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $3803
1926.1053 B01
- Issued
- Sep 8, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $3,803 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface, the ladder's lside rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about June 28, 2017; Second floor area of new residential construction; employees were using a step ladder to access the work area, which was an estimated 5 feet too short, exposing them to an estimated 25-30 foot fall to ground level or 10 foot fall to the deck area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $3803
1926.1053 B13
- Issued
- Sep 8, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about June 28, 2017; Second floor area of new residential construction; employees were using the top step of a 5-foot step ladder to access the work area exposing them to a 10 foot fall to the wooden floor area or an estimated 25-30 feet to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342483310.