MINCO, OK —
OSHA Inspection: ACCUFAB OF OKLAHOMA LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACCUFAB OF OKLAHOMA LLC in 1023 SW GIN ROAD, MINCO, OK 73059 (NAICS 332999). OSHA activity number 342485620.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCUFAB OF OKLAHOMA LLC
- Site address
- 1023 SW GIN ROAD
- City
- MINCO
- State
- OK
- ZIP
- 73059
- Mailing
- 1023 SW GIN ROAD, MINCO, OK 73059
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 11
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.179 G01 IV
- Issued
- Nov 1, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $2,173 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(iv): Multiple conductor cable was used with a suspended pushbutton station, but the station was not supported in some satisfactory manner that protected the electrical conductors against strain: On or about July 20, 2017, pendant control for overhead crane was not supported in manner that protected electrical conductors against strain. Employees were exposed to electric shock.
Recent events (2)
- — I (S) $1000
- — Z (S) $2173
1910.212 A01
- Issued
- Nov 1, 2017
- Abate by
- Nov 17, 2017
- Penalty
- Initial $2,173 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about July 20, 2017, unused portion of the blade on the HEM band saw was not guarded. Employees were exposed to the hazard of being struck by blade.
Recent events (2)
- — I (S) $1000
- — Z (S) $2173
1910.303 G01 II
- Issued
- Nov 1, 2017
- Abate by
- Nov 9, 2017
- Penalty
- Initial $2,173 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On or about July 20, 2017, the required working space around electrical equipment was used for storage. Employees were exposed to the hazards associated with fire.
Recent events (2)
- — I (S) $1000
- — Z (S) $2173
1910.22 D01
- Issued
- Nov 1, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were not supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. On or about July 20, 2017, area used for storage did not have approved loads marked on plates of approved design and securely affixed to the building. Employees were exposed to the hazard of being struck by falling equipment and/or boxes.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C01
- Issued
- Nov 1, 2017
- Abate by
- Nov 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about July 20, 2017, the employer did not establish and implement a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) for employees who were required to wear tight fitting half face-piece respirators. Employees were exposed to respiratory hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Accufab of Oklahoma LLC
View Accufab of Oklahoma LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342485620.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.