FRIDAY HARBOR, WA ·
OSHA Inspection: NATIONAL PARK SERVICE SAN JUAN ISLAND NATIONAL HISTORIC PARK, HEADQUARTERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE SAN JUAN ISLAND NATIONAL HISTORIC PARK, HEADQUARTERS in 650 MULLIS STREET, FRIDAY HARBOR, WA 98250 (NAICS 712190). OSHA activity number 342486594.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 650 MULLIS STREET
- City
- FRIDAY HARBOR
- State
- WA
- ZIP
- 98250
- Mailing
- P.O. BOX 429, FRIDAY HARBOR, WA 98250
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 9
- Ownership type
- Federal government (D)
Citations
8 citations on file for this inspection.
1910.36 D01
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors. a) Office Suite Hallway, where the designated emergency exit discharge door was equipped with a dead bolt lock that required turning the knob to unlock the door.
Recent events (1)
- · Z (S) $0
1910.37 B02
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Office Suite, where designated emergency exit doors not equipped with exit signs included: 1. Main Entrance discharge door. 2. Hallway, where the discharge door was equipped with a damaged exit sign.
Recent events (1)
- · Z (S) $0
1910.37 B04
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Where the direction of travel to the exit or exit discharge was not immediately apparent, signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge: a) Office Suite Hallway, where directional signs were not posted along the exit access.
Recent events (1)
- · Z (S) $0
1910.157 E02
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) Office Suite, where fire extinguishers not inspected on a monthly basis included: 1. Kitchen, where no records of inspection were maintained for the First Alert fire extinguisher. 2. Superintendents Office, where the inspection tag on the Kidde fire extinguisher was dated 6/15/2013.
Recent events (1)
- · Z (O) $0
1910.157 E03
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Office suite, where fire extinguishers not inspected annually included: 1. Kitchen, where no records of inspection were maintained for the First Alert fire extinguisher. 2. Superintendents Office, where the annual inspection tag on the Kidde fire extinguisher was dated December 2006.
Recent events (1)
- · Z (O) $0
1910.303 B02
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with instructions included in the listing or labeling: a) Office Suite, where electrical equipment not used as listed or labeled included: 1. Front Entrance Desk, where a relocatable power tap was daisy chained with an extension cord and available for use. 2. Archaeologist Technician Cubicle, where two relocatable power taps were daisy chained and used to supply power to computer and electronic equipment.
Recent events (1)
- · Z (O) $0
1910.305 G01 IV A
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Office Suite, where extension cords used as a substitute for fixed wiring included: 1. Education Specialist Cubicle, where an extension cord was used to supply power to the desk lighting.
Recent events (1)
- · Z (O) $0
1960.25 C
- Issued
- Aug 24, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.25(c): The Agency did not inspect annually, all areas in each workplace, including office operations: a) Facility, where an annual inspection of the workplace had not been conducted.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 712190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342486594.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.