OSHA Inspection: NATIONAL PARK SERVICE SAN JUAN ISLAND NATIONAL HISTORIC PARK, HEADQUARTERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE SAN JUAN ISLAND NATIONAL HISTORIC PARK, HEADQUARTERS in 650 MULLIS STREET, FRIDAY HARBOR, WA 98250 (NAICS 712190). OSHA activity number 342486594.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service SAN Juan Island National Historic Park, Headquarters for free Get an email when a new federal OSHA severe-injury report for National Park Service SAN Juan Island National Historic Park, Headquarters is published. One employer, no account, unsubscribe in one click.
Site address
650 MULLIS STREET
City
FRIDAY HARBOR
State
WA
ZIP
98250
Mailing
P.O. BOX 429, FRIDAY HARBOR, WA 98250
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
9
Ownership type
Federal government (D)

8 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.   a) Office Suite Hallway, where the designated emergency exit discharge door was equipped with a dead bolt lock that required turning the knob to unlock the door.
Recent events (1)
  • · Z (S) $0

1910.37 B02

Serious Gravity 1 4 instances 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":    a) Office Suite, where designated emergency exit doors not equipped with exit signs included:   1. Main Entrance discharge door.  2. Hallway, where the discharge door was equipped with a damaged exit sign.
Recent events (1)
  • · Z (S) $0

1910.37 B04

Serious Gravity 1 1 instance 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Where the direction of travel to the exit or exit discharge was not immediately apparent, signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge:   a) Office Suite Hallway, where directional signs were not posted along the exit access.
Recent events (1)
  • · Z (S) $0

1910.157 E02

Other-than-serious 2 instances 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    a) Office Suite, where fire extinguishers not inspected on a monthly basis included:  1. Kitchen, where no records of inspection were maintained for the First Alert fire extinguisher.  2. Superintendents Office, where the inspection tag on the Kidde fire extinguisher was dated 6/15/2013.
Recent events (1)
  • · Z (O) $0

1910.157 E03

Other-than-serious 2 instances 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   a) Office suite, where fire extinguishers not inspected annually included:   1. Kitchen, where no records of inspection were maintained for the First Alert fire extinguisher.   2. Superintendents Office, where the  annual inspection tag on the Kidde fire extinguisher was dated December 2006.
Recent events (1)
  • · Z (O) $0

1910.303 B02

Other-than-serious 2 instances 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with  instructions included in the listing or labeling:   a) Office Suite, where electrical equipment not used as listed or labeled included:   1. Front Entrance Desk, where a relocatable power tap was daisy chained with an extension cord and available for use.   2. Archaeologist Technician Cubicle, where two relocatable power taps were daisy chained and used to supply power to computer and electronic equipment.
Recent events (1)
  • · Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a) Office Suite, where extension cords used as a substitute for fixed wiring included:  1. Education Specialist Cubicle, where an extension cord was used to supply power to the desk lighting.
Recent events (1)
  • · Z (O) $0

1960.25 C

Other-than-serious 1 instance 9 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1960.25(c): The Agency did not inspect annually, all areas in each workplace, including office operations:   a) Facility, where an annual inspection of the workplace had not been conducted.