Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VETERANS HOME IMPROVEMENTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VETERANS HOME IMPROVEMENTS in 28-32 OLEAN ROAD, EAST AURORA, NY 14052 (NAICS 238160). OSHA activity number 342489788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veterans Home Improvements — free Get an email when a new federal OSHA severe-injury report for Veterans Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
28-32 OLEAN ROAD
City
EAST AURORA
State
NY
ZIP
14052
Mailing
32 EUCLID AVENUE, KENMORE, NY 14217
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 28, 2017
Penalty
Initial $1,385 · Current $1,385
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) On or about 7/18/17 at a roof replacement project located at 28-32 Olean Road, East Aurora, New York; employees working on the ground below active roof operations were not wearing hard hats.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1385

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 28, 2017
Penalty
Initial $2,309 · Current $2,309
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used:  a) On or about 7/18/17 at a roof replacement project located at 28-32 Olean Road, East Aurora, New York; employees were using a ladder jack scaffold, with the scaffold brackets and platform to the outside of the supporting ladders. The employees accessed the platform by climbing the supporting ladders and climbing around the bracket and platform.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2309

1926.451 G01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 28, 2017
Penalty
Initial $2,309 · Current $2,309
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a) On or about 7/18/17 at a roof replacement project located at 28-32 Olean Road, East Aurora, New York; employees performing roofing activities from a ladder jack scaffold approximately 18 feet high were not protected from falling by a personal fall arrest system.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2309

1926.501 B11

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 28, 2017
Penalty
Initial $2,309 · Current $2,309
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) On or about 7/18/17 at a roof replacement project located at 28-32 Olean Road, East Aurora, New York; employees working on the roof were removing shingles on the roof of a two story house. The roof had a 8 in 12 pitch and an eave heights of approximately 20 feet. There was no fall protection in use.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2309

1926.1053 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 28, 2017
Penalty
Initial $2,309 · Current $2,309
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about 7/18/17 at a roof replacement project located at 28-32 Olean Road, East Aurora, New York; an extension ladder used for access to the ladder jack scaffold was only 1'-6" above the platform surface.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2309

View Veterans Home Improvements's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342489788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.