GOLDEN, CO —
OSHA Inspection: C.F. MAIER COMPOSITES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of C.F. MAIER COMPOSITES, INC. in 16531 TABLE MOUNTAIN PKWY., GOLDEN, CO 80403 (NAICS 326199). OSHA activity number 342501129.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C.F. MAIER COMPOSITES, INC.
- Site address
- 16531 TABLE MOUNTAIN PKWY.
- City
- GOLDEN
- State
- CO
- ZIP
- 80403
- Mailing
- 16531 TABLE MOUNTAIN PKWY., GOLDEN, CO 80403
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 72
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 31, 2017
- Abate by
- Sep 27, 2017
- Penalty
- Initial $4,310 · Current $3,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: 1) On July 25, 2017, and at prior times, employees were exposed to fire hazards, in that a catalyst containing methyl ethyl ketone peroxide, an organic peroxide, was stored near flammable liquids such as styrene inside the flammable storage room. Among other methods, some feasible and acceptable methods to abate the hazard are to: a) ensure that organic peroxide storage conforms with NFPA 400- Hazardous Materials Code, which states Incompatible materials and flammable liquids shall not be stored within 25 ft. (7.6 m) of organic peroxide formulations. (Chapter 14.3.2.9-1) b) store products containing MEKP in a separate, approved flammable storage cabinet or room from flammable liquids stored in the flammable storage room.
Recent events (3)
- — F (S) $3000
- — C (S) $4310
- — Z (S) $4310
1910.106 E02 II A
- Issued
- Aug 31, 2017
- Abate by
- Oct 19, 2017
- Penalty
- Initial $4,310 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(a): Except as provided in subdivisions (b) and (c) of this subdivision, all storage shall comply with paragraph (d) (3) or (4) of this section: 1) On July 25, 2017, and at prior times, the flammable liquid storage room did not have a mechanical or gravity ventilation system, as required by 1910.106(d)(4)(iv). 2) On July 25, 2017, and at prior times, category 3 flammable liquids with a flash point below 100 degrees F were stored in the flammable liquid storage room. The light fixture in the room was not approved for Class I, Division 2 hazardous locations as required by 1910.106(d)(4)(iii), in that the cover for the fixture was missing and the light bulb was exposed.
Recent events (3)
- — F (O) $3000
- — C (S) $4310
- — Z (S) $4310
1910.107 E02
- Issued
- Aug 31, 2017
- Abate by
- Sep 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of Category 2, 3 or 4 flammable liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons: 1) On July 25, 2017, and at prior times, approximately 165 gallons of gel coat, a category 3 flammable liquid, was stored outside of an approve storage room in the production area.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.133 A01
- Issued
- Aug 31, 2017
- Abate by
- Sep 27, 2017
- Penalty
- Initial $4,310 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: 1) On August 1, 2017, and at prior times, the employer did not ensure that employees wore appropriate eye protection while working with methyl ethyl ketone peroxide (MEKP), a chemical with potential to cause severe eye injuries.
Recent events (3)
- — F (O) $3000
- — C (S) $4310
- — Z (S) $4310
1910.1200 F06 II
- Issued
- Aug 31, 2017
- Abate by
- Sep 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals was labeled with a product identifier and with general information regarding the hazards of the chemicals: 1) On July 25, 2017, and at prior times, secondary containers of catalyst containing MEKP were not labeled with a product identifier and the hazards of the chemical.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at C.F. Maier Composites, INC.
View C.F. Maier Composites, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342501129.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.