JACKSONVILLE, FL —
OSHA Inspection: SNAA LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SNAA LLC in 3811 UNIVERSITY BLVD WEST NO. 16 AND 18, JACKSONVILLE, FL 32217 (NAICS 327991). OSHA activity number 342510971.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SNAA LLC
- Site address
- 3811 UNIVERSITY BLVD WEST NO. 16 AND 18
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32217
- Mailing
- 3811 UNIVERSITY BLVD WEST NO. 18, JACKSONVILLE, FL 32217
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 A04
- Issued
- Nov 15, 2017
- Abate by
- Apr 16, 2018
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a. On or about August 31, 2017, in the fabrication area, the employer did not obtain the manufacturer's prior written approval before installing a LM-EBT-4 front-end attachment to the "Clark COP-23" which affected the lifting capacity of the industrial truck and to the capacity, operation, and maintenance instruction plates, tags, or decals were not changed accordingly.
Recent events (1)
- — Z (S) $1630
1910.178 L
- Issued
- Nov 15, 2017
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: a. On or about August 31, 2017, in the fabrication area, the employer did not ensure that the forklift operators were competent to safely operate a "Clark COP-23" powered industrial truck safely, as demonstrated by the successful completion of training and evaluation.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Nov 15, 2017
- Abate by
- Apr 16, 2018
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. On or about August 31, 2017, in the fabrication area, an electrical box with a Yaskawa J1000 VF Drive used to power a "Magnum 5" wet stone router was hung from a 2x4 piece of lumber on a hand car instead of installed securely on a wall or other building's structure. If the cart and box fall onto the wet floor and the VF Drive or the conductors are damaged or disconnected, a fault could occur and the box and floor could become energized, exposing the employees to electrical energy and suffer an electrical shock.
Recent events (1)
- — Z (S) $2173
1910.1200 E01
- Issued
- Nov 15, 2017
- Abate by
- Apr 16, 2018
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a. On or about July 31, 2017, in the fabrication area, the employer failed to developed or implemented a written hazard communication program for the protection of the employees who use chemical cleaners and adhesives during the fabrication of countertops, including Denatured Alcohol Solvent, Acetone, GranQuartz Transparent Knife Grade Polyester Adhesive, Tenax-Pectro and Tenax-Crystal.
Recent events (1)
- — Z (S) $1630
1910.134 C02 I
- Issued
- Nov 15, 2017
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. On or about July 31, 2017, in the fabrication area, the employer failed to provide the information contained in the appendix D of the Respiratory Protection Standard to the employees who were provided respirators for voluntary use.
Recent events (1)
- — Z (O) $0
1910.242 B
- Issued
- Nov 15, 2017
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. On or about August 31, 2017, in the fabrication area, the employer failed to ensure that the employees using compress-air for the cleaning of countertops, used nozzles where the pressure was reduced from approximately 104 psi to less than 30 psi or that the nozzles were equipped with a safety tip, to protect employees from possible injury to the eyes or embolism.
Recent events (1)
- — Z (O) $0
More inspections at Snaa LLC
View Snaa LLC's full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342510971.