Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ALLIANCE TANK SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALLIANCE TANK SERVICE in 2530 PORT PLACE, MUSKOGEE, OK 74403 (NAICS 236210). OSHA activity number 342511433.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alliance Tank Service for free Get an email when a new federal OSHA severe-injury report for Alliance Tank Service is published. One employer, no account, unsubscribe in one click.
Site address
2530 PORT PLACE
City
MUSKOGEE
State
OK
ZIP
74403
Mailing
PO BOX 1311, CUSHING, OK 74023
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Other-than-serious 2 instances 2 exposed
Issued
Aug 23, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    Tank erection area:  On or about July 26, 2017, employees were erecting a steel tank section by section with the use of a crane.  Some employer were not wearing the available hardhats.  This exposed them struck by hazards.
Recent events (2)
  • · I (O) $3803
  • · Z (S) $3803

1926.350 A10

Other-than-serious 6 instances 5 exposed
Issued
Aug 23, 2017
Abate by
Aug 25, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:    Tank erection area:  On or about July 26, 2017, and times prior to, employees engaged in the erection of steel tanks used  and worked around acetylene and oxygen cylinders.  Spare oxygen cylinders were stored with the acetylene in use.  This exposed the employees to the hazards of fire.
Recent events (2)
  • · I (O) $3803
  • · Z (S) $3803

1926.352 D

Other-than-serious 1 instance 5 exposed
Issued
Aug 23, 2017
Abate by
Aug 25, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.352(d): Suitable fire extinguishing equipment was not immediately available in the work area(s) where welding, cutting, or heating was being performed:    Tank erection area:  On or about July 26, 2017, and times prior to, employees were engaged in the erection of two new storage tanks at a liquid feed mill using acetylene/oxygen to cut the steel tank components and arc welding to assemble the components.  There were no fire extinguishers posted for immediate use exposing the employees to the hazards of fire.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3803

1926.404 B01 I

Other-than-serious 1 instance 4 exposed
Issued
Aug 23, 2017
Abate by
Aug 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  Tank erection area:  On or about July 26, 2017, and times prior to, employees erecting a steel tank use an angle grinder powered through an extension cord.  The cord was connected to a receptacle in the adjoining building.  No ground fault protection was provided exposing the employees to the hazard of electrical shock.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342511433.