BROOKLYN, NY —
OSHA Inspection: TIGRE HOME IMPROVEMENT CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIGRE HOME IMPROVEMENT CORP in 354A PROSPECT AVE, BROOKLYN, NY 11215 (NAICS 238140). OSHA activity number 342512449.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIGRE HOME IMPROVEMENT CORP
- Site address
- 354A PROSPECT AVE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11215
- Mailing
- 94-08 42ND AVENUE APT. #3, CORONA, NY 11368
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 9
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Jan 29, 2018
- Abate by
- Feb 8, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. Site: 354 A Prospect Ave, Brooklyn, NY. On or about 8/1/2017 a) Employees worked on the 4th & 5th frame high platforms on a tubular welded frame scaffold that was not fully planked.
Recent events (1)
- — Z (S) $3880
1926.451 C01
- Issued
- Jan 29, 2018
- Abate by
- Feb 8, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. Site: 354 A Prospect Ave, Brooklyn, NY. On or about 8/1/2017 a) The employer used ropes to anchor the scaffold frames to the window guards of the building for stability. Employees worked from the 5th frame of a tubular welded frame scaffold.
Recent events (1)
- — Z (S) $2772
1926.451 E01
- Issued
- Jan 29, 2018
- Abate by
- Feb 8, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Site: 354 A Prospect Ave, Brooklyn, NY. On or about 8/1/2017 a) Employees worked on a tubular welded frame scaffold and it did not have safe means of access. Employees climbed the cross bars and frames to access the scaffold.
Recent events (1)
- — Z (S) $3880
1926.451 F07
- Issued
- Jan 29, 2018
- Abate by
- Feb 8, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Site: 354 A Prospect Ave, Brooklyn, NY. On or about 8/1/2017 a) The scaffold used on site was not erected under the supervision and direction of a competent person qualified in scaffold erection. The scaffold deficiencies consisted of but not limited to working platforms not fully planked, missing guards rails and endrails, was not tied to prevent tipping, and had no safe means of access.
Recent events (1)
- — Z (S) $2772
1926.451 G04 I
- Issued
- Jan 29, 2018
- Abate by
- Feb 8, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: Site: 354 A Prospect Ave, Brooklyn, NY. On or about 8/1/2017 a) Employees worked from the 5th frame of a tubular welded frame scaffold which was not equipped with guardrails. Employees exposed to a fall of approximately 27 feet.
Recent events (1)
- — Z (S) $3880
1926.501 B03
- Issued
- Jan 29, 2018
- Abate by
- Feb 8, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems: Site: 354 A Prospect Ave, Brooklyn, NY. On or about 8/1/2017 a) An employee hoisting material from the scaffold platform to the ground level was exposed to a fall of approximately 24 feet. The employee was not provided with fall protection.
Recent events (1)
- — Z (S) $3880
More inspections at Tigre Home Improvement Corp
View Tigre Home Improvement Corp's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342512449.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.