Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPER LOPEZ FOOD PRODUCTS AND TORTILLA FACTORY INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SUPER LOPEZ FOOD PRODUCTS AND TORTILLA FACTORY INC. in 7314 HARRISBURG BLVD, HOUSTON, TX 77011 (NAICS 311830). OSHA activity number 342512480.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Super Lopez Food Products and Tortilla Factory INC. — free Get an email when a new federal OSHA severe-injury report for Super Lopez Food Products and Tortilla Factory INC. is published. One employer, no account, unsubscribe in one click.
Site address
7314 HARRISBURG BLVD
City
HOUSTON
State
TX
ZIP
77011
Mailing
7314 HARRISBURG BLVD, HOUSTON, TX 77011
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311830
Employees
25
Ownership type
A

18 citations on file for this inspection.

1910.95 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Apr 16, 2018
Penalty
Initial $3,696 · Current $2,772 Reduced

Hazardous substances 8111

29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:    a)  On corn tortilla line #1, where an employee stacking tortillas was exposed to 81% of noise dose. Sampling was conducted for 399 minutes on August 16, 2017.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $3696

1910.95 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Apr 16, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:    a)  On corn tortilla line #1, where an employee stacking tortillas was exposed to 81% of noise dose. Sampling was conducted for 399 minutes on August 16, 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 I02 II A

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(i)(2)(ii)(A): The employer did not ensure that hearing protectors are worn by any employee who is exposed to an 8-hour time-weighted average of 85 decibels or greater and has not yet had a baseline audiogram established pursuant to 29 CFR 1910.95(g)(5)(ii):  a)  On corn tortilla line #1, where an employee stacking tortillas was exposed to 81% of noise dose. Sampling was conducted for 399 minutes on August 16, 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 19, 2018
Abate by
Apr 2, 2018
Penalty
Initial $5,174 · Current $3,881 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     a)  At the facility, where procedures had not been developed, documented and utilized for the control of potentially hazardous energy when employees changed and repaired belts on the Casa Herrera Model CCT-5T, serial number 03062432.
Recent events (2)
  • — I (S) $3881
  • — Z (S) $5174

1910.147 C05 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 19, 2018
Abate by
Feb 23, 2018
Penalty
Initial $5,174 · Current $3,880 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources:     a)  At the facility, where locks and tags for the isolation of the Casa Herrera Model CCT-5T, serial number 03062432 were not provided to maintenance employees.
Recent events (2)
  • — I (S) $3880
  • — Z (S) $5174

1910.147 C07 I

Serious Gravity 10 1 instance 25 exposed
Issued
Jan 19, 2018
Abate by
Apr 2, 2018
Penalty
Initial $5,174 · Current $3,881 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    a)  Throughout the facility, where employees had not received training that ensured they understood the purpose and function of the energy control program and that they had acquired the knowledge and skills required for the safe application, use, and removal of energy control devices.
Recent events (2)
  • — I (S) $3881
  • — Z (S) $5174

1910.157 C04

Serious Gravity 5 3 instances 25 exposed
Issued
Jan 19, 2018
Abate by
Jan 31, 2018
Penalty
Initial $3,696 · Current $2,772 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:     a)  On or about August 11, 2017, in the fryer area, a portable fire extinguisher was not fully charged.      b)  On or about August 16, 2017, adjacent to the Peerless Dough Mixer, a portable fire extinguisher was not fully charged.      c)  On or about August 16, 2017, in the packaging area, a portable fire extinguisher was not fully charged.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $3696

1910.157 C01

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 19, 2018
Abate by
Jan 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a)  On or about August 16, 2017, in the packaging area, a portable fire extinguisher  was blocked.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 10 3 instances 25 exposed
Issued
Jan 19, 2018
Abate by
Jan 25, 2018
Penalty
Initial $5,174 · Current $3,880 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:     a)  On or about July 28, 2017, the path to ground from the chip hopper was not permanent, continuous and effective.        b)  On or about August 11, 2017, the path to ground from the inclined conveyor was not permanent, continuous and effective.        c)  On or about August 11, 2017, the path to ground from a Maxx Air Pro floor fan was not permanent, continuous and effective.
Recent events (2)
  • — I (S) $3880
  • — Z (S) $5174

1910.303 B02

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 19, 2018
Penalty
Initial $2,217 · Current $1,663 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  on or about July 28, 2017, a relocatable power tap (RPT) was connected to an extension cord, in contravention to its listing and labeling.
Recent events (2)
  • — I (S) $1663
  • — Z (S) $2217

1910.303 B08 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 19, 2018
Penalty
Initial $2,217 · Current $1,662 Reduced
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it is mounted:     a)  on or about August 11, 2017, an outlet box, being used to energize the hopper, was  mounted on the floor and was not secured.
Recent events (2)
  • — I (S) $1662
  • — Z (S) $2217

1910.334 A02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:   a)  On or about August 11, 2017, where a frayed black extension cord was in used to power the hopper.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 19, 2018
Abate by
Jan 31, 2018
Penalty
Initial $2,217 · Current $1,663 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     a)  on or about August 11, 2017, the branch circuits controlling the wrapping machine were not labeled.
Recent events (2)
  • — I (S) $1663
  • — Z (S) $2217

1910.305 B01 I

Serious Gravity 5 3 instances 12 exposed
Issued
Jan 19, 2018
Abate by
Jan 31, 2018
Penalty
Initial $3,696 · Current $2,772 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:    a)  On August 11, 2017, openings through which conductors entered on the Yaskawa GPR 315/V7 were not closed.      b)  On August 16, 2017, openings through which conductors entered the Ziehl-Abegg fan were not closed.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $3696

1910.305 D02

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 19, 2018
Abate by
Jan 25, 2018
Penalty
Initial $3,696 · Current $2,772 Reduced
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front:     a)  On August 16, 2017, behind the Peerless Dough Mixer, a circuit breaker box lacked a panelboard, exposing energized parts.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $3696

1910.147 C01

Repeat Gravity 10 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Apr 2, 2018
Penalty
Initial $10,347 · Current $7,760 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a)  Throughout the facility, where an energy control program was not established.    Super Lopez Food Products and Tortilla Factory was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1120058, citation number 1, item number 1 and was affirmed as a final order on July 26, 2016, with respect to a workplace located at 7314 Harrisburg Boulevard, Houston, Texas.
Recent events (2)
  • — I (R) $7760
  • — Z (R) $10347

1910.305 B01 II

Repeat Gravity 5 1 instance 12 exposed
Issued
Jan 19, 2018
Abate by
Jan 31, 2018
Penalty
Initial $7,391 · Current $5,519 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were bot effectively closed:     a) On August 11, 2017, unused openings on the Yaskawa GPR 315/V7 were not closed.    Super Lopez Food Products and Tortilla Factory was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1120058, citation number 1, item number 4 and was affirmed as a final order on July 26, 2016, with respect to a workplace located at 7314 Harrisburg Boulevard, Houston, Texas.
Recent events (2)
  • — I (R) $5519
  • — Z (R) $7391

1904.29 A

Other-than-serious 1 instance 25 exposed
Issued
Jan 19, 2018
Abate by
Jan 31, 2018
Penalty
Initial $739 · Current $555 Reduced
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent:    a)  at the facility, an OSHA 300 log was not used to record all work-related injuries and fatalities.    Abatement Certification and Documentation is required.
Recent events (2)
  • — I (O) $555
  • — Z (O) $739

View Super Lopez Food Products and Tortilla Factory INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342512480.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.