Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIR FLOW PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AIR FLOW PRODUCTS, INC. in 24 PARK AVENUE, HUEYTOWN, AL 35023 (NAICS 333415). OSHA activity number 342517968.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Flow Products, INC. — free Get an email when a new federal OSHA severe-injury report for AIR Flow Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
24 PARK AVENUE
City
HUEYTOWN
State
AL
ZIP
35023
Mailing
24 PARK AVENUE, HUEYTOWN, AL 35023
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
41
Ownership type
A

2 citations on file for this inspection.

1910.217 C02 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 8, 2017
Abate by
Sep 20, 2017
Penalty
Initial $6,464 · Current $5,926 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):    (a) On or about 06/05/2017 - Boots Department, BLISS mechanical power press plate, serial #52, employees were exposed to amputation hazards due to the 3-inch gap between the steel plates.
Recent events (2)
  • — I (S) $5925.5
  • — Z (S) $6464

1904.39 A02

Deleted Other-than-serious 1 instance 1 exposed
Issued
Sep 8, 2017
Penalty
Initial $5,387 · Current $0 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:   (a) On or about 08/01/2017 - Air Flow Products, Inc., an injury that occurred on 06/05/2017 that resulted in a medical amputation on 07/07/2017 was not reported to OSHA.
Recent events (2)
  • — I (O) $0
  • — Z (O) $5387

View AIR Flow Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342517968.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.