Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARTISTIC PLATING CO., INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ARTISTIC PLATING CO., INC. in 405 W. CHERRY ST, MILWAUKEE, WI 53212 (NAICS 332813). OSHA activity number 342523164.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Artistic Plating CO., INC. — free Get an email when a new federal OSHA severe-injury report for Artistic Plating CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
405 W. CHERRY ST
City
MILWAUKEE
State
WI
ZIP
53212
Mailing
405 W. CHERRY ST, MILWAUKEE, WI 53212
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
68
Ownership type
A

4 citations on file for this inspection.

1910.132 D01

Serious Gravity 1 2 instances 8 exposed
Issued
Dec 21, 2017
Abate by
Jan 11, 2018
Penalty
Initial $3,232 · Current $2,262 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:   (a)     The employer's personal protective equipment (PPE) policy and hazard assessment regarding minimum PPE required to be used by Plating Operators in the Plating Department was deficient, in-that it did not include required use of impermeable aprons to protect  Plating Operators from exposure to splashing or dripping of corrosive liquids, such as Nitric Acid used in the passivation tanks in the Gold Room.    (b)    The employer's personal protective equipment (PPE) policy and hazard assessment regarding minimum PPE required to be used by Plating Operators in the Plating Department was deficient, in-that it did not clearly address required foot wear or use of protective shoe or boot coverings to protect Plating Operators from exposure to splashing or dripping of corrosive liquids, such as Nitric Acid used in the passivation tanks in the Gold Room.
Recent events (2)
  • — I (S) $2262.4
  • — Z (S) $3232

1910.303 E01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 21, 2017
Abate by
Jan 19, 2018
Penalty
Initial $3,232 · Current $2,262 Reduced
29 CFR 1910.303(e)(1)(i): Electric equipment was used without the manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product could be identified.  (a)    In the Plating Area of the Gold Room, a wall-mounted electrical circuit breaker panelboard with visible corrosion on it was not labeled  with the manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product could be identified.
Recent events (2)
  • — I (S) $2262.4
  • — Z (S) $3232

1910.303 G01 VII

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(vii): Switchboards, panel boards, and distribution boards installed for the control of light and power circuits, and motor control centers were not located in dedicated spaces and protected from damage:  a)    In the Plating Area of the Gold Room, a wall-mounted electrical circuit breaker panelboard with visible corrosion on it, indicating that it was not adequately protected from damage from corrosive substances.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 21, 2017
Abate by
Jan 19, 2018
Penalty
Initial $3,232 · Current $2,262 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) On or about August 4, 2017, in the Plating Area of the Gold Room a 25 ft. extension cord, which traversed walkways used by employees, potentially exposed the cord to damage and exposed employees to a tripping hazard. The electrical extension was being used to power a portable electroplating barrel in the "Co Hard Gold Plating Tank" (Tank #01-031).
Recent events (2)
  • — I (S) $2262.4
  • — Z (S) $3232