SENECA FALLS, NY —
OSHA Inspection: SENECA FALLS SPECIALTIES & LOGISTICS COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SENECA FALLS SPECIALTIES & LOGISTICS COMPANY, INC. in 50 JOHNSTON STREET, SENECA FALLS, NY 13148 (NAICS 493110). OSHA activity number 342525409.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SENECA FALLS SPECIALTIES & LOGISTICS COMPANY, INC.
- Site address
- 50 JOHNSTON STREET
- City
- SENECA FALLS
- State
- NY
- ZIP
- 13148
- Mailing
- 50 JOHNSTON STREET, SENECA FALLS, NY 13148
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.37 A03
- Issued
- Nov 2, 2017
- Abate by
- Dec 7, 2017
- Penalty
- Initial $4,346 · Current $2,608 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a. At the facility, on or about 8/4/17: An emergency exit door was blocked by a 2 x 4 across its width. The 2 x 4 prevented egress through the door in one fluid movement. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2607.6
- — Z (S) $4346
1910.215 A04
- Issued
- Nov 2, 2017
- Abate by
- Dec 7, 2017
- Penalty
- Initial $4,346 · Current $2,608 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. In the maintenance shop, on or about 8/4/17: A BG-8 bench grinder was being operated with its work rest one and one half inch away from the periphery of the abrasive wheel. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2607.6
- — Z (S) $4346
1910.215 B09
- Issued
- Nov 2, 2017
- Abate by
- Dec 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. In the maintenance shop, on or about 8/4/17: A BG-8 bench grinder was being operated with its tongue guard one inch from the periphery of the abrasive wheel. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Nov 2, 2017
- Abate by
- Dec 7, 2017
- Penalty
- Initial $4,346 · Current $2,608 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. : a. In the wood shop, on or about 8/4/17: Employee using compressed air at 120 p.s.i.for cleaning with an air wand which was not equipped with any type of pressure relief device. Abatement certification must be submitted for this item
Recent events (2)
- — I (S) $2607.6
- — Z (S) $4346
1910.303 G02 I
- Issued
- Nov 2, 2017
- Abate by
- Dec 7, 2017
- Penalty
- Initial $2,897 · Current $1,738 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a. On the production floor at the power panel for the #1 box making machine, on or about8/4/17: A 240 volt electrical outlet was not equipped with a cover and had exposed live parts. Abatement documentation must be submitted for this item.
Recent events (2)
- — I (S) $1738.2
- — Z (S) $2897
1910.305 G02 III
- Issued
- Nov 2, 2017
- Abate by
- Dec 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. In the box making area, on or about 8/4/17: The power cord to box machine #1 had been damaged and as a result was lacking adequate strain relief. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Seneca Falls Specialties & Logistics Company, INC.
View Seneca Falls Specialties & Logistics Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342525409.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.