HILTON HEAD ISLAND, SC ·
OSHA Inspection: PALMETTO BAY YACHT REPAIR, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PALMETTO BAY YACHT REPAIR, LLC in 75 HELMSMAN WAY, HILTON HEAD ISLAND, SC 29928 (NAICS 336612). OSHA activity number 342525623.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALMETTO BAY YACHT REPAIR, LLC
- Site address
- 75 HELMSMAN WAY
- City
- HILTON HEAD ISLAND
- State
- SC
- ZIP
- 29928
- Mailing
- 75 HELMSMAN WAY, HILTON HEAD ISLAND, SC 29928
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 9
- Ownership type
- Private (A)
Citations
19 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $2,716 · Current $1,494 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing injuries from a tractor equipped with ROPs, overturning or from the operator falling off the tractor due to the tractor not being equipped with seat belts. Among other methods, one feasible and acceptable method to correct this hazard is for the employer to provide and then require the use of the operator restraint system (seat belt) a) Worksite: Employees operating a John Deere model 5410 tractor, used for odd lifting and towing jobs was not equipped with seat belts. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- · I (S) $1494
- · Z (S) $2716
1910.178 L
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $2,173 · Current $1,195 Reduced
General-duty citation text
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: a) Worksite: Employees operating the Marine Travelift boat hoist, had not been trained in it's safe operation.
Recent events (2)
- · I (S) $1195
- · Z (S) $2173
1910.212 B
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $1,630 · Current $897 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Southeast end of Shop: A Grizzly heavy duty drill press, model G1200 was found to be top-heavy and it was not securely anchored to the concrete floor. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (S) $897
- · Z (S) $1630
1910.213 C01
- Issued
- Oct 26, 2017
- Abate by
- Jan 8, 2018
- Penalty
- Initial $3,803 · Current $2,092 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) South end of the Shop: A Powermatic table saw was used without a hood or guard of any kind while cutting wood stock.
Recent events (2)
- · I (S) $2092
- · Z (S) $3803
1910.213 C02
- Issued
- Oct 26, 2017
- Abate by
- Jan 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) South end of the Shop: A Powermatic table saw was not equipped with a spreader during cutting operations.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.213 C03
- Issued
- Oct 26, 2017
- Abate by
- Jan 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) South end of the Shop: A Powermatic table saw was not equipped with dogs to prevent the material being cut from being thrown back onto the operator.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.304 G05
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $1,630 · Current $897 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Southeast end of Shop: The 120 volt electrical cord for the Grizzly heavy duty drill press, model G1200 was missing the ground prong. b) South wall of the Shop: The 120 volt electrical cord for the DeWalt circular saw was missing the ground prong. ABATEMENT CERTICATION IS REQUIRED
Recent events (2)
- · I (S) $897
- · Z (S) $1630
1910.305 B01
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $1,630 · Current $897 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed: a) Southeast corner of the Shop: A 120 volt quad receptacle outlet box used to supply power to a drill press and a Coke machine had three (3) one (1) inch openings which were not effectively closed. b) South wall of Storage Room behind Back Office: A 220 volt junction box was found to have a 2 inch opening exposing the wiring contained therein. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (S) $897
- · Z (S) $1630
1910.305 B02 I
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) North wall of the Break Room: A quad receptacle outlet supplying power to a microwave oven and a refrigerator was not equipped with a faceplate. b) Supervisors Front Office: Three (3) receptacle outlets used to power battery chargers etc. were not provided with faceplates ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 J02 VII
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: a) Southwest corner of Yard: A 120 volt outside electrical duplex receptacle outlet was not provided with a cover which would close when a cord was removed. b) West end of Yard: A 120 volt outside electrical duplex receptacle outlet was not provided with a cover which would close when a cord was removed. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1915.81 A03
- Issued
- Oct 26, 2017
- Penalty
- Initial $2,716 · Current $1,494 Reduced
General-duty citation text
29 CFR 1915.81(a)(3): The employer shall store materials in a manner that does not create a hazard for employees. a) Center of Back Shop: Employees entering the shop area had to pass directly underneath a wooden shelf which was attached to the ceiling with nails and metal banding. The shelf held eight (8) metal yacht propellers. There was no rail to keep them from slipping off the shelf, and it is unclear if the shelf was constructed in a manner that it could safely hold that much weight.
Recent events (2)
- · I (S) $1494
- · Z (S) $2716
1915.152 A
- Issued
- Oct 26, 2017
- Abate by
- Jan 8, 2018
- Penalty
- Initial $2,716 · Current $1,494 Reduced
General-duty citation text
29 CFR 1915.152(a): The employer did not provide or ensure each affected employee with the appropriate personal protective equipment (PPE) for the eyes, face, head, extremities, torso, and respiratory system, including protective clothing, protective barriers, personal fall protection equipment, and life saving equipment, meeting the applicable provisions of Subpart I, wherever employees were exposed to work activity hazards that required the use of PPE. a) Graving Dock: Employees working from the top of a graving dock while helping lift vessels from the water with a boat hoist, were exposed to falling into the water 4.5 feet below. No life jackets were worn. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (S) $1494
- · Z (S) $2716
1910.37 B02
- Issued
- Oct 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) East end of the building: Front entrance door was not marked by a sign reading "Exit" b) West end of the building: Two rear entrance doors were not marked by a sign reading "Exit"
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B02
- Issued
- Oct 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) South wall of the front lobby area: A relocatable power tap, designed and listed for being used with high concentrations of low powered loads was instead used with high powered loads such as a coffee maker.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.304 A02
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity: a) West end of the Boatyard: An outdoor receptacle outlet used at the site to power extension cords and power tools was found to have reversed polarity. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 A02 IX
- Issued
- Oct 26, 2017
- Abate by
- Dec 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. a) C.C.'s Room: Two (2) light sets of two (2) fluorescent lights each were located 7-feet, 3-inches from the floor and they were not protected from breakage by a guard or other suitable means. b) South wall of Main Shop Area: A "sun lamp" clamped to one of the doors to a flammable storage locker was used for lighting and the light bulb was not protected from breakage by a guard or other suitable means. c) Back Shop Area: Three (3) light sets of two (2) fluorescent lights each were located 7-feet, 3-inches from the floor and they were not protected from breakage by a guard or other suitable means. d) Corner Office and Break Room: Three (3) light sets of two (2) fluorescent lights each were located 7-feet, 3-inches from the floor and they were not protected from breakage by a guard or other suitable means. e) Hot House: Three (3) light sets of two (2) fluorescent lights each were located 7-feet, 6-inches from the floor and they were not protected from breakage by a guard or other suitable means.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 G01 IV A
- Issued
- Oct 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) East end of the Main Shop: A 120 volt Coke Machine was plugged into an extension cord instead of being plugged directly into a wall receptacle outlet.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.334 A02 II
- Issued
- Oct 26, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Southeast corner of the Shop: An extension cord used to power a drill press had the outer insulation separated from the male plug-end was showing 1.5 inches of the insulated individual wires underneath. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
1915.152 B
- Issued
- Oct 26, 2017
- Abate by
- Jan 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.152(b): The employer did not assess its work activity to determine whether there were hazards present, which necessitate the employee's use of personal protective equipment. a) Worksite: The employer could not provide the required documentation that a Personal Protective Equipment Assessment had been conducted at the site. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Palmetto BAY Yacht Repair, LLC
View Palmetto BAY Yacht Repair, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in SC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342525623.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.