On , OSHA opened a complaint safety inspection of HARD CORE SPIRAL TUBE WINDERS INC. in 2 ROUTE 27, RAYMOND, NH 03077 (NAICS 322219). OSHA activity number 342525748.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hard Core Spiral Tube Winders INC. — free Get an email when a new federal OSHA severe-injury report for Hard Core Spiral Tube Winders INC. is published. One employer, no account, unsubscribe in one click.
Site address
2 ROUTE 27
City
RAYMOND
State
NH
ZIP
03077
Mailing
PO BOX 823, EXETER, NH 03833
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322219
Employees
7
Ownership type
A

11 citations on file for this inspection.

1910.37 A03

Other-than-serious 1 instance 6 exposed
Issued
Oct 30, 2017
Abate by
Nov 3, 2017
Penalty
Initial $3,622 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    Site- Employees were not protected from fire and entrapment hazards where the building exit discharge to the exit door adjacent to the bathrooms was blocked by a second outer building door which was locked. The interior exit door was marked as an exit door.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3622

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Nov 17, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    Site- Employees operating a Toyota 8FGU25 forklift were not provided with operator training from the employer.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.178 O05

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Nov 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(o)(5): A load engaging means was not placed under the load as far as possible; the mast was not carefully tilted backward to stabilize the load:  Site- Employees were not protected from struck by hazards where loads on the forklift were not stabilized during travel by tilting the mast backward due to loads consisting of two pallets on top of each other with the top pallet being above the back rest of the forks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 30, 2017
Abate by
Nov 17, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a. Site- Employees operating the older Prima recutter were not protected from amputation and severe laceration hazards where the point of operation was not guarded.    b. Site- Employees were not protected from amputation and severe lacerations hazards where powered rollers on the portable, blue, single paper roll, glue station were not guarded.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.219 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Jan 8, 2018
Penalty
Initial $3,622 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    Site- Employees were not protected from severe laceration and amputations hazards where the upper and lower pulleys on the winding machine were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3622

1910.219 E03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Jan 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    Site- Employees were not protected from severe laceration and amputations hazards where the vertical belt on the winding machine was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 30, 2017
Abate by
Nov 17, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    Site- Employees were not protected from electric shock and fire hazards where electrical equipment on the winding and glue machines was covered combustible paper dust and exposed live parts were present.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Nov 3, 2017
Penalty
Initial $3,622 · Current $0 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    Site- Employees were not protected from electric shock where electrical equipment on the glue station operating at 208 volts was in a control box where the doors to the box were not effectively closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3622

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Jan 8, 2018
Penalty
Initial $2,173 · Current $1,087 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    Site- Employees were not protected from electric shock where each panel board did not have each circuit breaker marked to identify its purpose.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1910.178 A04

Other-than-serious 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  Site- The employer did not obtain prior written approval to use a carpet pole attachment and fork extensions with their Toyota 8FGU25 forklift.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Oct 30, 2017
Abate by
Nov 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Site- The working space in front of panel boards at the back of the production floor were used for storage of production materials.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342525748.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.