CONCORD, MA ·
OSHA Inspection: QUALITY AND PERFECTION INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of QUALITY AND PERFECTION INC. in 149 BELKNAP STREET, CONCORD, MA 01742 (NAICS 238320). OSHA activity number 342526829.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY AND PERFECTION INC.
- Site address
- 149 BELKNAP STREET
- City
- CONCORD
- State
- MA
- ZIP
- 01742
- Mailing
- 185 IRVING STREET APT. 3F, FRAMINGHAM, MA 01702
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 5
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 18, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 149 Belknap Street, Concord, MA 01742 On or about July 26, 2017, the employer did not ensure that employees engaged in residential construction activities 6 feet or more above lower levels were protected by guardrail systems, safety net system, or personal fall arrest system. An employee was conducting vacuuming work on the rear roof of the house without a personal fall arrest system or other means of fall protection. There is no abatement documentation or certification required for this item.
Recent events (1)
- · Z (S) $3880
1926.1053 B16
- Issued
- Jan 18, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. 149 Belknap Street, Concord, MA 01742 On or about July 26, 2017, the employer did not ensure that portable ladders with structural defects were immediately marked in a manner that readily idenfies them as defective, or tagged with "Do Not Use" or similar language and were not withdrawn from service until repairs: a) The employer did not ensure that a ladder in the rear of the house with a broken foot was removed from service. b) The employer did not ensure that a ladder in the front of the house without feet was removed from service. There is no abatement documentation or certification required for this item.
Recent events (1)
- · Z (S) $3880
1926.1053 B01
- Issued
- Jan 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 149 Belknap Street, Concord, MA 01742 On or about July 26, 2017, the employer did not ensure that portable ladders used for access to an upper landing surface extended at least 3 feet above the upper landing surface being accessed. A ladder used to access the rear roof was not extended 3 feet above the upper landing surface. There is no abatement documentation or certification required for this item.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238320)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342526829.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.