Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: CONSTRUCTION MANAGEMENT & MAINTENANCE COMPANY INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CONSTRUCTION MANAGEMENT & MAINTENANCE COMPANY INC. in HIGHWAY 16/HIGHWAY 13, SEARCY, AR 72143 (NAICS 238210). OSHA activity number 342536315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Construction Management & Maintenance Company INC. — free Get an email when a new federal OSHA severe-injury report for Construction Management & Maintenance Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
HIGHWAY 16/HIGHWAY 13
City
SEARCY
State
AR
ZIP
72143
Mailing
#4 PERIN ROAD, NORTH LITTLE ROCK, AR 72118
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
10
Ownership type
A

9 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $3,803 · Current $1,902 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:     On or about August 9, 2017, and times prior thereto, inside an unprotected confined footing trench excavation greater than 4 feet in depth, employees jackhammering did not have a safe means of egress.
Recent events (3)
  • — F (S) $1901.5
  • — C (S) $3803
  • — Z (S) $3803

1926.651 G01 II

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $3,803 · Current $1,902 Reduced
29 CFR 1926.651(g)(1)(ii): Adequate precautions were not taken to prevent employee exposure to atmospheres containing less than 19.5 percent oxygen and other hazardous atmospheres:    On or about August 9, 2017, and times prior thereto, in a confined footing trench excavation, where the employer did not provide oxygen and silica content air monitoring prior to employees entering to perform jackhammering.
Recent events (3)
  • — F (S) $1901.5
  • — C (S) $3803
  • — Z (S) $3803

1926.651 G01 IV

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.651(g)(1)(iv): When controls were used that were intended to reduce the level of atmospheric contaminants to acceptable levels, testing was not conducted as often as necessary to ensure that the atmosphere remained safe:  On or about August 9, 2017, and times prior thereto, in a confined footing trench excavation, where employees were jackhammering and using an air hose for ventilation without atmospheric testing was being conducted.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:  On or about August 9, 2017, and times prior thereto, in a confined footing trench excavation, where employees were jackhammering, an inspection of the possible atmospheric hazards was not conducted by a competent person.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.651 G02 II

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $3,803 · Current $1,902 Reduced
29 CFR 1926.651(g)(2)(ii): The life-line provided for employee entering bell-bottom pier holes, or other similar deep and confined footing excavations, was not separate from any line used to handle materials:    On or about August 9, 2017, and times prior thereto, in a confined footing trench excavation, where employees life-lines used for entry were attached to the material handling winch line of an Altec digger derrick.
Recent events (3)
  • — F (S) $1901.5
  • — C (S) $3803
  • — Z (S) $3803

1926.652 B02

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.652(b)(2): Maximum allowable slopes, and allowable configurations for sloping and benching systems, was not determined in accordance with the conditions and requirements set forth in Appendices A and B to this subpart:   On or about August 9, 2017 and times prior thereto, in a confined footing trench excavation, where employees were performing jackhammering, the soil and rock deposits had not been adequately classified by a competent person as Stable Rock, Type A, Type B, or Type C.
Recent events (3)
  • — F (S) $0
  • — C (S) $3803
  • — Z (S) $3803

1910.134 C01

Other-than-serious 1 instance 5 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $305 · Current $153 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103):      On or about August 9, 2017, and times prior thereto, at the jobsite, the employer had not developed and implemented a written respiratory protection program for employees required to wear half facepiece respirators.
Recent events (3)
  • — F (O) $152.5
  • — C (O) $305
  • — Z (O) $305

1910.134 G01 I A

Other-than-serious 1 instance 5 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (Construction Reference 1926.103)(a):  On or about August 9, 2017, and times prior thereto, in a confined footing trench excavation, employees who had facial hair were assigned to wear half facepiece respirators with organic cartridges while using a jackhammer.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1926.1417 C01

Other-than-serious 1 instance 5 exposed
Issued
Oct 17, 2017
Abate by
Oct 31, 2017
Penalty
Initial $305 · Current $153 Reduced
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, were not readily available in the cab at all times for use by the operator:    On or about August 9, 2017, and times prior thereto, at the jobsite, the operator's manual was not in the cab of the Altec D-3060 Digger Derrick, Serial No. CA0318 for use by the operator.
Recent events (3)
  • — F (O) $152.5
  • — C (O) $305
  • — Z (O) $305

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342536315.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.