BELLEFONTAINE, OH ·
OSHA Inspection: ALLIED WASTE SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALLIED WASTE SYSTEMS, INC. in 2946 US ROUTE 68 NORTH, BELLEFONTAINE, OH 43311 (NAICS 562111). OSHA activity number 342539491.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLIED WASTE SYSTEMS, INC.
- Site address
- 2946 US ROUTE 68 NORTH
- City
- BELLEFONTAINE
- State
- OH
- ZIP
- 43311
- Mailing
- 2946 US ROUTE 68 NORTH, BELLEFONTAINE, OH 43311
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562111
- Employees
- 60
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C07 I
- Issued
- Nov 9, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. On or about April 10, 2017, the employer did not ensure employees were adequately trained in the purpose and function of the energy control program. Employees were required to perform activities such as performing servicing and maintenance of the hydraulic systems on automated side loader refuse trucks, and are exposed to struck by and caught in hazards from moving parts in that the equipment was not properly deenergized.
Recent events (3)
- · J (S) $0
- · C (S) $12675
- · Z (S) $12675
1910.147 D05 I
- Issued
- Nov 9, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $12,675 · Current $7,436 Reduced
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a.) On August 1, 2017, the employer did not ensure that all residual energy was restrained while performing maintenance on the side arm of the #2401 McNeilus automated side loader refuse truck (Model 42). An employee was performing maintenance on the raised hydraulic side arm, when it unexpectedly released pressure and came down on the employees arm, resulting in crushing injuries.
Recent events (3)
- · J (S) $7436
- · C (S) $12675
- · Z (S) $12675
More inspections at Allied Waste Systems, INC.
View Allied Waste Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342539491.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.