OSHA Inspection: SCHNEID CONSTRUCTION CO., INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of SCHNEID CONSTRUCTION CO., INC. in 51 LELAND AVENUE, UTICA, NY 13502 (NAICS 238140). OSHA activity number 342540853.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schneid Construction CO., INC. for free Get an email when a new federal OSHA severe-injury report for Schneid Construction CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
51 LELAND AVENUE
City
UTICA
State
NY
ZIP
13502
Mailing
210 SIXTH NORTH STREET, SYRACUSE, NY 13208
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 B04

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 12, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm):    a) On or about 8/10/2017, Lime Stabilization Building:  Outrigger scaffold planks located on the West side of the building above the 4th stage of tubular welded frame scaffolding were not cleated or restrained while they were extending between 2 and 4 inches from their support.  Employees exposed to falls of 30 feet.
Recent events (2)
  • · I (S) $3042
  • · Z (S) $5070

1926.451 F03

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 12, 2017
Abate by
Oct 24, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a) On or about 8/10/2017, Lime Stabilization Building:  Tubular welded frame scaffolding was not inspected by a competent person after alterations were made, such as, but not limited to the removal of guardrails, and the addition of outrigger platforms.  Employees exposed to falls of up to 30 feet.      Abatement documentation is required for this item.
Recent events (2)
  • · I (S) $3042
  • · Z (S) $5070

1926.451 G01 VI

Serious Gravity 10 6 instances 5 exposed
Issued
Oct 12, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity):    a) On or about 8/10/2017, Lime Stabilization Building:  Numerous areas on the Tubular welded frame scaffolding were lacking a proper guardrail system exposing employees to falls.  These areas included but are not limited to:      1) No guardrail system at the interior, near ladder on the South East corner, third tier.  Employees exposed to falls of 19.25 feet.      2) No guardrail system on the exterior, near ladder on the South East corner, third tier.  Employees exposed to falls of 19.25 feet.      3) No guardrail system on the interior, South East corner, fourth tier.  Employees exposed to falls of 26 feet.       4) No guardrail system on the interior for one bay, and no midrail for the remainder of the South side, fourth tier, interior.  Employees exposed to falls of 26 feet.      5) No guardrail system on the fourth tier, South West corner, interior.  Employees exposed to falls of 26 feet.      6) No top rail or functional midrail on the outrigger above the fourth tier, West side.  Employees exposed to falls of 30 feet.