BELTON, MO —
OSHA Inspection: ROM CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ROM CORPORATION in 6800 E. 163 ST., BELTON, MO 64012 (NAICS 333999). OSHA activity number 342541604.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROM CORPORATION
- Site address
- 6800 E. 163 ST.
- City
- BELTON
- State
- MO
- ZIP
- 64012
- Mailing
- 6800 E. 163 ST., BELTON, MO 64012
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 140
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 8, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $6,652 · Current $3,991 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Employees were exposed to caught-by hazards. Employees were observed operating the TRAK DMP3 milling machine in the maintenance area with rotating parts that was not guarded to prevent the employee from being pulled into the work area.
Recent events (2)
- — I (S) $3991.2
- — Z (S) $6652
1910.215 A04
- Issued
- Jan 8, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $8,315 · Current $4,989 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Employees were exposed to struck-by hazards. In the Utilities area an employee was operating a bench grinder to sharpen tools and the guard was adjusted to an open position.
Recent events (2)
- — I (S) $4989
- — Z (S) $8315
1910.215 B09
- Issued
- Jan 8, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $8,315 · Current $4,989 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Employees were exposed to struck-by hazards. In the Utilities area an employee was operating a bench grinder to sharpens tools and had the tongue guard fully lifted.
Recent events (2)
- — I (S) $4989
- — Z (S) $8315
1910.253 A03
- Issued
- Jan 8, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved: Employees were exposed to fire and explosion hazards. In the maintenance area a portable oxy-fuel torch cart had an acetylene regulator whose gage was missing a protective cover and was ready for use.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.303 B02
- Issued
- Jan 8, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $6,652 · Current $3,991 Reduced
8870
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Employee were exposed to electrical shock hazards. Listed or labeled relocatable power taps were not used or installed in accordance with instructions included in the listing or labeling which were in operation at 120 V. In the utilities area a relocatable power tap was connected in series (daisy chained) from a receptacle to power a portable hand grinder.
Recent events (2)
- — I (S) $3991.2
- — Z (S) $6652
1910.305 G02 III
- Issued
- Jan 8, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $8,315 · Current $4,989 Reduced
8870
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Employees were exposed to electrical shock hazards. In the facility there were a couple of instances where cord and cables were not provided strain relief. a) In the shipping area employees were using a portable fan that had exposed wiring from failed strain relief. b) In the fabrication area employees were using a portable hand grinder that had no visible strain relief.
Recent events (2)
- — I (S) $4989
- — Z (S) $8315
1910.334 A02 I
- Issued
- Jan 8, 2018
- Penalty
- Initial $8,315 · Current $4,989 Reduced
8870
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): Employees were exposed to electrical shock hazards associated with cord a plug equipment. In the facility there were several instances where cord and plug equipment was missing a ground pin. a) In the ramp and carrier area a portable pedestal fan was in use and was missing its ground pin. b) In the shipping area a portable fan was in use and was missing its ground pin. b) In the fabrication area portable hand grinder was in use and was missing its ground pin.
Recent events (2)
- — I (S) $4989
- — Z (S) $8315
1910.178 M05 I
- Issued
- Jan 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not netralized, power was not shut off, and brakes set. Employees were exposed to struck-by hazards. This was demonstrated when the employer failed to protect employees from being struck by a powered industrial truck that was left unattended and the parking brake was not set.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ROM Corporation
View ROM Corporation's full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342541604.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.