DENVER, CO ·
OSHA Inspection: QUINN PROCESS EQUIPMENT COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of QUINN PROCESS EQUIPMENT COMPANY in 3400 BRIGHTON BLVD., DENVER, CO 80216 (NAICS 423810). OSHA activity number 342545290.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUINN PROCESS EQUIPMENT COMPANY
- Site address
- 3400 BRIGHTON BLVD.
- City
- DENVER
- State
- CO
- ZIP
- 80216
- Mailing
- 3400 BRIGHTON BLVD., DENVER, CO 80216
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423810
- Employees
- 8
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.1200 E01
- Issued
- Sep 15, 2017
- Abate by
- Oct 20, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a)Quinn Process Equipment Company at 3400 Brighton Blvd, Denver, CO: On and before August 14, 2017, the employer did not develop, implement, and maintain at the workplace a site specific written hazard communication program. Employees are potentially exposed to hazardous chemicals, including but not limited to the following: 1) Argon compressed gas 2) Slugger Cutting Fluid 3) Rustlick 631 4) Anti-Spatter Aerosol 5) Gloss Protective Enamel 6) Rusty Metal Primer
Recent events (2)
- · I (S) $1630
- · Z (S) $1630
1910.1200 G08
- Issued
- Sep 15, 2017
- Abate by
- Oct 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: (a) Quinn Process Equipment Company at 3400 Brighton Blvd, Denver, CO: On and before August 14, 2017, the employer did not maintain the required safety data sheets for each hazardous chemical in the workplace. The employer had not updated material safety data sheets to safety data sheet under the Globally Harmonized System. This condition exposed employees to chemical hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Sep 15, 2017
- Abate by
- Oct 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Quinn Process Equipment Company at 3400 Brighton Blvd, Denver, CO: On and before March 17, 2017, the employer did not provide employees with effective information and training on hazardous chemicals in their work area. Employees did not know the hazards of the chemicals in their work areas. This condition exposed employees to chemical hazards, including but not limited to Argon Compressed gas, Slugger Cutting Fluid, Rustlick 631, Anti-Spatter Aerosol, Gloss Protective Enamel, and Rusty Metal Primer. Abatement Note: Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through Globally Harmonized System labels and safety data sheets.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C02 I
- Issued
- Sep 15, 2017
- Abate by
- Oct 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (a) Quinn Process Equipment Company at 3400 Brighton Blvd, Denver, CO: On and before August 14, 2017, the employer did not ensure that any employee using a respirator voluntarily was provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible. The employer provided 3M Model 8211 N95 filtering facepiece respirators for voluntary use. This condition exposed the employees to a respiratory hazard.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 G01 I
- Issued
- Sep 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: (a) Quinn Process Equipment Company at 3400 Brighton Blvd, Denver, CO: On and before August 14, 2017, the employer did not maintain a workspace of at leave 30 inches wide in front of four electrical panels located on walls in the northwestern, northeastern, southwestern and southeastern regions of the fabrication shop. The electrical breaker panels were blocked by work benches, equipment, metal sheets and shelving. This condition potentially exposed employee to hazards associated emergency incidents in which equipment and machines must be immediately de-energized.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1026 D01
- Issued
- Sep 15, 2017
- Abate by
- Oct 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): (a) Quinn Process Equipment Company at 3400 Brighton Blvd, Denver, CO: On and before March 25, 2017, the employer did not ensure that employee exposure to chromium (VI) was assessed, while stick welding and hand grinding on stainless steel. An employee was exposed to an eight-hour time weighted average concentration of 4.48 micrograms per cubic meter of chromium (VI) when sampled for 401 minutes. The employee exposure was above the action level but below the permissible exposure limit for chromium (VI).
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 423810)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342545290.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.